Setting Up Auto-Configuration

The default frame relay discovery mode is 1MPort. If you do not want management
links configured or auto-configuration, change the default setting for FR Discovery. The
following table describes the difference between the various settings.

FR Discovery Mode

Description

1MPort

(Default)

Auto-configuration is enabled, and for each DLCI
discovered on the network, a multiplexed network DLCI
and a standard port DLCI will be configured and
connected. The multiplexed network DLCI will contain
one EDLCI for management traffic, and one EDLCI for
customer data. The customer data EDLCI on the network
will be cross-connected to the data port DLCI.

1Port

Auto-configuration is enabled. For each DLCI discovered
on the network, a multiplexed network DLCI and a
standard port DLCI will be configured and connected,
creating a PVC within the FrameSaver unit. No
management DLCIs will be configured on the network
interface.

NetOnly

Auto-configuration is enabled, DLCIs are discovered on
the network interface, but no cross-connections are
configured.

Disable

No frame relay discovery takes place. No DLCIs will be
configured on the network interface. The user must
manually configure the FrameSaver unit.

See 

Using Auto-Configuration in Chapter 3, Typical Applications, and Setting Up

Automatic Configuration in Chapter 8, Setup, of the User’s Guide for more information.

To change the default setting for FR Discovery:

1. Select Auto-Configuration.

Main Menu

Auto-Configuration

2. Select another frame relay discovery mode (FR Discovery).

3. Press Ctrl-a to move the cursor to the bottom of the screen.

4. Type s (Save) and press Enter. The Delete All DLCIs and PVC Connections?

prompt will appear. Type y  ( Yes) and press Enter.

5. Press Esc three times to return to the Main Menu.

Summary of Contents for FrameSaver SLV 9x24 Series

Page 1: ...Within the U S A call 1 800 PARADYNE 1 800 727 2396 Outside the U S A call 1 727 530 8623 Before You Begin If you ordered a wall mounting kit Feature No 9001 F1 891 for your 1 slot FrameSaver unit in...

Page 2: ...quick and trouble free installation Do not install your cables until instructed to do so Safety Instructions Please refer to the EMI Warnings and Important Safety Instructions beginning on page 24 Pac...

Page 3: ...Part Number T1 Line interface connector For use in Canada T1 line interface cable RJ48C to CA81A 3100 F1 510 LAN Customer converter with a DB25 plug on one end and an 8 pin modular jack on the other e...

Page 4: ...king tab snaps securely into the jack POWER COM NETWORK DSX 1 98 15823 Power Cord Transformer Insert the 3 prong plug into an ac outlet O K A L M The front panel OK LED lights 2 3 3 Prong Grounded AC...

Page 5: ...ameSaver unit s COM port 98 15824 POWER COM NETWORK DSX 1 To Connect to a PC or Async Terminal COM Port FrameSaver 9124 Shown 3 Insert the other end of the cable into the VT100 compatible terminal 4 T...

Page 6: ...replacement of the power supply An LED is not lit LED is burned out Run the Lamp Test If the LED in question does not flash with the other LEDs contact your sales or service representative Power Up S...

Page 7: ...n changing a configuration option All the available settings for an option appears at the bottom of the screen As an example follow these steps to go to the Configuration Edit Display menu so you can...

Page 8: ...selection sequence from the Main Menu pressing Enter after each selection Main Menu Status System and Test Status 2 Check the Self Test Results column in the center of the System and Test Status scree...

Page 9: ...rface time slot number that will be assigned to the DSX 1 interface Press the spacebar until the appropriate DSX 1 channel is displayed Helpful Hint All unconnected DSX 1 channels will appear for assi...

Page 10: ...and Communication Communication Protocol 2 Minimally enter the following options Node IP Address Node Subnet Mask 3 Press Esc once to return to the Management and Communication menu 4 Select General S...

Page 11: ...rd port DLCI will be configured and connected creating a PVC within the FrameSaver unit No management DLCIs will be configured on the network interface NetOnly Auto configuration is enabled DLCIs are...

Page 12: ...4 it is a RJ48S DDS network cable 2 Insert the other end of the cable into the RJ48C T1 or RJ48S DDS modular jack POWER COM NETWORK DSX 1 98 15826 Jack RJ48C FrameSaver 9124 RJ48S FrameSaver 9624 Fram...

Page 13: ...Information of the User s Guide for possible reasons for the messages and what can be done to resolve the problem Proceed to Entering Trap Managers on page 14 Verification Check for a FrameSaver 9624...

Page 14: ...tral site s NMS trap manager SNMP Traps set to Enable Number of Trap Managers NMS n IP Address n being the first second third etc trap manager entered 3 Press Ctrl a to move the cursor to the bottom o...

Page 15: ...rk interface Configuration Edit Display Network DLCI Records 2 Type o Modify and press Enter The Modify DLCI Record for DLCI Number prompt will appear 2 Select the DLCI that will be used by pressing t...

Page 16: ...eing pinged then select Start NOTE When running tests the cursor is positioned over the Start command Press Enter to start the test Stop is displayed while the test is running Press Enter again to iss...

Page 17: ...king frames from the PVC and looping them back Main Menu Test Network PVC Tests PVC Loopback 4 On the remote site unit send a pattern over the network interface and monitor it Main Menu Test Network P...

Page 18: ...alarm LEDs off If yes the DSX interface is set up correctly and operational If no check that both ends of the DSX cable are properly seated and secured 2 Check Health and Status messages in the left...

Page 19: ...check that both ends of the V 35 cable are properly seated and secured 2 Check Health and Status messages in the left column of the System and Test Status screen for messages Main Menu Status System...

Page 20: ...the counts that are displayed See Chapter 11 Displaying System Information of the User s Guide for additional status information See Chapter 13 Troubleshooting for additional troubleshooting informati...

Page 21: ...0 123 mA at 120 Vac Average power 6 6 watts 120 Vac 12 Vac 60 Hz 3 Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 32 F to 122 F 0 C to 50 C 4 F t...

Page 22: ...Fractional T1 service frame relay service RJ48C CA81A using adapter cable D4 ESF AMI B8ZS 0 0 dB 7 5 dB 15 dB 22 5 dB Selectable FCC Part 68 AT T TR 62411 Selectable DSX 1 Interface FrameSaver SLV 912...

Page 23: ...actional T1 rates automatically set to the network rate 56 or 64 kbps automatically set to the network rate Pin Assignments Since FrameSaver SLV 9x24s have standard connectors there is no need to orde...

Page 24: ...he power cord and do not locate the product where persons will walk on the power cord 7 General purpose cables are provided with this product Special cables which may be required by the regulatory ins...

Page 25: ...equipment unless the changes or modifications are expressly approved by Paradyne WARNING To Users of Digital Apparatus in Canada This Class A digital apparatus meets all requirements of the Canadian...

Page 26: ...Mbps SF and B8ZS without line power 04DU9 1KN 1 544 Mbps ANSI ESF without line power 04DU 1SN 1 544 Mbps ANSI ESF and B8ZS without line power After the telephone company has installed the requested s...

Page 27: ...of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the s...

Page 28: ...oc eng paradyne com Include the number and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional clarification Trademarks All...

Reviews: