4 Operation
4-14
FrameSaver NP 64+ User’s Manual - Installation Guide
980-001-0221C
March
2001
Frame Manager
Configuration
The Frame Manager Configuration screen allows you to view and alter parameters for
Frame Manager operations.
The Frame Manager Configuration screen is shown in Figure 4-5.
Figure 4-5 Frame Manager Configuration Screen
Configure Frame Manager
1. WAN Mgmt DLCI - Displays current DLCI value of the private network PVC or
Tunneled PVC for WAN management of the FrameSaver NP 64+, as stored in the
unit’s non-volatile memory (NVM). This value may be entered using the unit’s
rear panel DLCI DIP Switches (except for “relearn” mode), or entered from this
screen. Enter only DLCI number for private network PVC, preface the DLCI
number with “T” for tunneled PVC, or preface the DLCI number with “D” for
relearn mode. In relearn mode, the WAN management DLCI will be automatically
relearned each time the PVC returns to an “active” condition.
2. P/C Mgmt DLCI - Sets or disables the direction and PVC for Payload/CPE
management access to the FrameSaver NP 64+. The first letter (P or C) determines
which direction, and the remainder indicates the DLCI value.
NOTE: The P/C Mgmt DLCI value must NOT be the same as WAN Mgmt DLCI.
CAUTION
If either WAN or P/C Mgmt DLCI value is changed, the
FrameSaver NP 64+ will perform a system reset after the
Save [SA] command is issued. The system reset will
terminate any console session in progress and interrupt
data traffic.
************************** Frame Manager Configuration *************************
Name: F@43802
LMI Protocol [P=]
WAN Mgmt DLCI [D=#,T#orD#]: Disabled 1) None 3) "LMI"
P/C Mgmt DLCI [E=P#orC#]: Disabled >>2) ANSI"D" << 4) ITU"A"
X to Disable or 16 thru 991
------------- Network ------------ -------------- User --------------
T391/Status Enq Rate [S1=#]: 10 T392/Status Enq Timeout [S2=#]: 15
5 thru 30 seconds 5 thru 30 seconds
N392/Event Err Thres [T1=#]: 3 N392/Event Error Thres [T2=#]: 3
N393/Event Count [C1=#]: 4 N393/Event Count [C2=#]: 4
1 thru 10 1 thru 10
N391/Full Status Freq [F1=#]: 6 Force Full Status Response [F2=]
1 thru 255 >>1) Disable<<
2) Enable
PVC BECN/FECN Thres [B=#]: Disabled
X to Disable or 1 thru 895 seconds
Link Err Thres [L1=#]: Disabled Link Err Thres [L2=#]: Disabled
X to Disable or 1 thru 895 seconds X to Disable or 1 thru 895 seconds
Help[?] Save[SA] Cancel[X]
>