COMSPHERE 392xPlus Modems
5-14
November 1996
3920-A2-GN31-30
Table 5-2
(9 of 9)
392x
Plus AT Commands
AT
Command
DCP LCD
Command
Sequence
Description
\N
n
Error Control Mode.
\N0
Buffer Mode.
\N1
Direct Mode.
\N2
MNP or Disconnect.
\N3
MNP or Buffer.
\N4
V.42/MNP or Disconnect.
\N5
V.42/MNP or Buffer.
\N6
LAPM or Disconnect.
\N7
LAPM or Buffer.
Configure\Edit\
V42/MNP/Buffer
\Q
n
Flow Control of DTE, Flow Control of Modem.
Flow Control
Flow Control
of DTE:
of Modem:
\Q0
Disable
Disable
\Q1
XON/XOFF
XON/XOFF
\Q2
CTS to DTE
Disable
\Q3
CTS to DTE
RTS to Mdm
\Q4
XON/XOFF
Disable
\Q5
Disable
XON/XOFF
\Q6
Disable
RTS to Mdm
Configure\Edit\
V42/MNP/Buffer
\T
n
No Data Disconnect Timer.
\T0
Disable.
\Tn
Where
n is a value from 1 to 255 in 1-minute increments.
Configure\Edit\
Line Dialer
NOTE: The factory default value is country dependent.
\X
n
XON/XOFF Passthrough Flow Control.
\X0
Disable.
\X1
Enable.
Configure\Edit\
V42/MNP/Buffer
%A
n
Error Control Fallback Character.
%An
Where
n is an ASCII value from 0 to 127. Factory default is 013
ASCII.
Configure\Edit\
V42/MNP/Buffer
%C
n
MNP5 Data Compression.
%C0
Disable.
%C1
Enable.
Configure\Edit\
V42/MNP/Buffer
I
H
n
V.42bis Compression.
I
H0
Disable.
I
H1
Enable (Transmit (TX) only).
I
H2
Enable (Receive (RX) only).
I
H3
Enable (Transmit (TX) and Receive (RX)).
Configure\Edit\
V42/MNP/Buffer