AT Command Set and S-Registers
5-11
3920-A2-GN31-30
November 1996
Table 5-2
(6 of 9)
392x
Plus AT Commands
AT
Command
DCP LCD
Command
Sequence
Description
&M
n and
&Q
n
Async/Sync Mode and DTE Dialer Type.
&M0, &Q0
Modem operates in Asynchronous mode using AT Command
protocol.
&M1, &Q1
Modem operates in Synchronous mode using AT Command
protocol.
&M2, &Q2
Modem operates in Synchronous mode and dials telephone number
stored in directory location 1 when DTR signal turns OFF and then
ON.
&M3, &Q3
Modem operates in Synchronous mode using AT Command
protocol.
&M231
Modem operates in Asynchronous mode using no AT Command
protocol.
&M232
Modem operates in Asynchronous mode using V.25bis
asynchronous AT Command protocol.
&M233
Modem operates in Synchronous mode using V.25bis
bisynchronous AT Command protocol.
&M234
Modem operates in Synchronous mode using V.25bis HDLC AT
Command protocol.
&M235
Modem operates in Asynchronous mode using AT&T Emulation AT
Command protocol.
&M236
Modem operates in Synchronous mode using no AT Command
protocol.
Configure\Edit\
DTE Dialer
The following commands disable the use of AT commands and force the modem
into Dumb mode: &M2, &Q2, &M231, &M232, &M233, &M234, &M235, &M236.
NOTE: The only way to gain control of the modem is via the DCP.
&R
n
RTS Action.
&R0
Standard RS232.
&R1
Ignores RTS.
&R2
Simulated Control Carrier.
&R3
Control Carrier.
Configure\Edit\
DTE Interface
&S
n
DSR Control.
&S0
Forced On.
&S1
Standard RS232.
&S2
Wink When Disconnect.
&S3
Follows DTR.
&S4
On Early.
&S5
Delay to Data.
Configure\Edit\