AT Commands and S-Registers
4-31
3825-A2-GB30-40
January 1999
Table 4-3
(3 of 3)
3825
Plus Security Commands
S97
DTE Password Termination Character
Determines ASCII value used to indicate the end of a password or Callback Directory/Number entered by the remote
user.
Enter a value from 1–63 or 123–127 for the command end character.
The factory setting is 13 (ASCII carriage return).
S98
DTE Password Backspace Character
Determines ASCII value used as the backspace (Backspace key) when entering a password or Callback
Directory/Number. This character moves the cursor to the left and erases the previous character.
Enter a value from 1–63 or 123–127.
The factory setting is 08 (ASCII backspace).
Summary of Contents for COMSPHERE 3825PLUS
Page 1: ...COMSPHERE 3825PLUS MODEM USER S GUIDE Document No 3825 A2 GB30 40 January 1999 ...
Page 4: ...COMSPHERE 3825Plus Modem C January 1999 3825 A2 GB30 40 Notices ...
Page 12: ...COMSPHERE 3825Plus Modem iv January 1999 3825 A2 GB30 40 This page intentionally left blank ...
Page 14: ...COMSPHERE 3825Plus Modem vi January 1999 3825 A2 GB30 40 This page intentionally left blank ...
Page 18: ...COMSPHERE 3825Plus Modem 1 4 January 1999 3825 A2 GB30 40 ...
Page 26: ...COMSPHERE 3825Plus Modem 3 2 January 1999 3825 A2 GB30 40 ...
Page 58: ...COMSPHERE 3825Plus Modem 4 32 January 1999 3825 A2 GB30 40 This page intentionally left blank ...
Page 70: ...COMSPHERE 3825Plus Modem B 6 January 1999 3825 A2 GB30 40 This page intentionally left blank ...
Page 80: ...COMSPHERE 3825Plus Modem E 6 January 1999 3825 A2 GB30 40 ...
Page 92: ...COMSPHERE 3825Plus Modem F 12 January 1999 3825 A2 GB30 40 This page intentionally left blank ...
Page 100: ...COMSPHERE 3825Plus Modem Glossary 8 January 1999 3825 A2 GB30 40 ...
Page 107: ...00282600 ...