Maintenance
4-7
3360-A2-GB20-10
June 1996
7. When you press F1 from the E1 Registers screen,
the E1 registers for the current 15-minute interval
appear.
F1
E1 Current:
Event =
xx,xxx
F2
F3
8. When you press F2 from the E1 Registers screen,
the E1 registers for the 24-hour total interval
appear.
F1
E1 24 Hour:
VldIntvl =
xx
F2
F3
9. When you press F3 from the E1 Registers screen,
the interval screen appears. Use this screen to
choose the specific 15-minute interval.
F1
E1 Intvl: 01
Up
Down
Dsply
F2
F3
10. Use the
and
keys to position the cursor
under the first or second digit in the interval
number displayed, then use the F1 (Up) and
F2 (Down) keys to increment/decrement the
number.
11. When you have selected the number of the interval
you want to display, press F3 (Dsply) to display
the registers for the interval selected. Use the
scroll keys to view additional register information.
F1
E1 Intvl:
xx
ES=
xxx
F2
F3
You can reset the performance registers via the ClrReg
command in the Control branch of the front panel menu.
To clear the performance registers,
1. From the top-level menu screen, press the
key
until the Ctrl selection appears on the screen.
2. Select Ctrl.
F1
E1 HDSL NTU
Test
Cnfig
Ctrl
F2
F3
3. From the Control screen, select ClrReg.
F1
Control:
Rel
LED
ClrReg
F2
F3
4. From the Clear Prf Regs screen, press F1 to clear
the E1 registers.
F1
Clear Prf Regs:
E1
HDSL
DTE
F2
F3
If you selected E1, the E1 performance registers
are cleared. All accumulators are reset to zero and
all status registers are cleared, and the current
interval timer, the number of valid intervals count
and the total 24-hour counts are reset to zero. The
Command Complete message then appears.