![Paradyne ACCULINK 3360 User Manual Download Page 134](http://html.mh-extra.com/html/paradyne/acculink-3360/acculink-3360_user-manual_753730134.webp)
SNMP MIB Objects
E-3
3360-A2-GB20-10
June 1996
Interface Group – “ifIndex” Object (ifEntry 1)
This object provides the index into the ifTable and
typically into tables in other MIBs also. The values of the
ifIndex object do not vary between models even though
not all indexes are supported for a particular model. When
an unsupported index is accessed, “noSuchName” is
returned.
The following are the values of the ifIndexes for all
33xx Series models:
•
1 – Net E1
•
2 – DTE E1
•
3 – COM port
•
4 – (not used)
•
5 – Auxiliary RS-232 port
•
6 – DCE port 1
•
7 – DCE port 2
•
8 – DCE port 3
•
9 – DCE port 4
The supported ifIndexes for the 3360 NTU are:
•
Net E1
•
DTE E1
•
COM port
•
Auxiliary RS-232 port
•
DCE port 1
•
DCE port 2
The supported ifIndexes for the 3364 NTU are:
•
Net E1
•
DTE E1
•
COM port
•
Auxiliary RS-232 port
•
DCE port 1
•
DCE port 2
•
DCE port 3
•
DCE port 4
The supported ifIndexes for the 3365 NTU are:
•
Net E1
•
DTE E1
•
COM port
•
Auxiliary RS-232 port
•
DCE port 1
Interface Group – “ifDescr” Object (ifEntry 2)
This object provides the textual information about the
interface. Each interface displays a text string as shown
below:
Network E1:
“Network E1. AT&T Paradyne E1
HDSL NTU, Hardware Version:
[CCA number for the CSU
board]”.
DTE E1:
“DTE E1. AT&T Paradyne E1
HDSL NTU, Hardware Version:
[CCA number for the CSU
board]”.
COM:
“COM port. AT&T Paradyne E1
HDSL NTU, Hardware Version:
[CCA number for the CSU
board]”.
AUX:
“AUX port. AT&T Paradyne E1
HDSL NTU, Hardware Version:
[CCA number for the CSU
board]”.
Data Ports:
“Data Port n. AT&T Paradyne E1
HDSL NTU, Hardware Version:
[CCA number for the DSU board]”
(where n is 1 to 4).
Interface Group – “ifType” Object (ifEntry 3)
This object identifies the type of the interface based on
the physical/link protocol(s) immediately below the
network layer. Only the following values are supported by
the E1 NTU:
•
e1(19) – Used for the network and G.703 DTE
interfaces.
•
propPointToPointSerial(22) – Used for the
synchronous data ports, and for the COM port when
the port is not configured as the SNMP
management interface.