Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or included in the

manual.

2. When an ac power source is used, this product is intended to be used with a 3-wire grounding

type plug – a plug which has a grounding pin. This is a safety feature. Equipment grounding is
vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by
modifying the plug or using an adapter.

Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the
presence of earth ground. If the receptacle is not properly grounded, the installation must not
continue until a qualified electrician has corrected the problem.

If a 3-wire grounding type power source is not available, consult a qualified electrician to
determine another method of grounding the equipment.

3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of

the product and to protect it from overheating, these slots and openings must not be blocked or
covered.

4. Do not allow anything to rest on the power cord and do not locate the product where persons

will walk on the power cord.

5. Do not attempt to service this product yourself, as opening or removing covers may expose

you to dangerous high voltage points or other risks. Refer all servicing to qualified service
personnel.

6. General purpose cables are provided with this product. Special cables, which may be required

by the regulatory inspection authority for the installation site, are the responsibility of the
customer.

7. When installed in the final configuration, the product must comply with the applicable Safety

Standards and regulatory requirements of the country in which it is installed. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.

8. A rare phenomenon can create a voltage potential between the earth grounds of two or more

buildings. If products installed in separate buildings are interconnected, the voltage potential
may cause a hazardous condition. Consult a qualified electrical consultant to determine
whether or not this phenomenon exists and, if necessary, implement corrective action prior to
interconnecting the products.

9. Input power to the ac voltage configuration of this product must be provided by a UL-listed or

CSA-certified power source with a Class 2 or Limited Power Source (LPS) output. Input power
to the dc voltage configurations of this product must be provided by a National Electric Code
(NEC) or a Canadian Electric Code (CEC) Class 2 circuit.

10. This product contains a coin cell lithium battery that is only to be replaced at the factory.

Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with
the same type. Dispose of used batteries according to the battery manufacturer’s instructions.
Attention: Il y a danger d’explosion s’il y a remplacement incorrect de la batterie. Remplacer
uniquement avec une batterie du même type. Mettre au rebut les batteries usagées
conformément aux instructions du fabricant.

11. In addition, if the equipment is to be used with telecommunications circuits, take the following

precautions:

Never install telephone wiring during a lightning storm.

Never install telephone jacks in wet locations unless the jack is specifically designed for
wet locations.

Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.

Use caution when installing or modifying telephone lines.

Avoid using a telephone (other than a cordless type) during an electrical storm. There may
be a remote risk of electric shock from lightning.

Do not use the telephone to report a gas leak in the vicinity of the leak.

 

Summary of Contents for ACCULINK 3163 DSU

Page 1: ...ACCULINK 3163 DSU CSU QUICK REFERENCE Document No 3163 A2 GL10 00...

Page 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Page 3: ...ore installing the DSU CSU read the Important Safety Instructions beginning on page 13 Quick Start Procedure The following procedure is for experienced DSU CSU users who are familiar with the 3163 DSU...

Page 4: ...LEDs blink twice When the test is complete verify that the DSU CSU is functional by observing that the OK and NETWORK SIG LEDs are lit PORT 1 COM PORT MODEM POWER NETWORK CAUTION AUX PORT OR COM PORT...

Page 5: ...ar Near Cur 8Tot Intvl Load Edit Area From Choose Function Activ Cust1 Cust2 Fact1 Fact2 User Alarm NET Port Chan Gen Mgmt Gen Save Cust1 Activ Cust2 Edit Cnfig Prt1 Clear Dsply Ctrl Rel ClrReg Reset...

Page 6: ...B Port initiated Loopbacks allows L b k t b i iti t d th h Port LB DCLB DCLB Loopbacks to be initiated through the port by the external DTE Both Both y Disab Disab All Ones DTR DTR All ones sent to ne...

Page 7: ...ab Disab Specifies whether the FDL s Mgmt Link SNMP SNMP S ecifies whether the FDLs Management Link is enabled NET LLB Enab Enab Network initiated LLB allows LLB to NET LLB Disab Disab Network initiat...

Page 8: ...60 704 616 768 672 832 728 896 784 960 840 1024 896 1088 952 1152 1008 1216 1064 1280 1120 1344 1176 1408 1232 1472 1288 1536 1344 64 56 128 112 192 168 256 224 320 280 384 336 448 392 512 448 576 504...

Page 9: ...N21 D21 N22 D22 N23 D23 N24 D24 This configuration option appears if the Assigned By configuration option is Block or ACAMI Line 1 Displays Line 2 Displays Meaning Comments Description Unassigned N1 N...

Page 10: ...t Enab Enab Allows bypass of self test on Self Test Disab Disab Allows by ass of self test on initialization FP Access Enab Enab Controls whether front panel FP Access Disab Disab Controls whether fro...

Page 11: ...5 1 5 Selects the number of stop bits for the COM port Stop Bits 2 2 the COM port Ignore DTR Yes Yes Specifies whether the COM port Ignore DTR No No S ecifies whether the COM ort ignores DTR CmInActTm...

Page 12: ...ab Enab Specifies whether the modem port di t ft t i i d Modem Port Inactivity Timeout Disab Disab disconnects after a certain period of inactivity 5 5 MoDiscTm Modem Port Up Up Specifies the period o...

Page 13: ...arm messages on MODEM port Call Retry Enab Enab Specifies whether an outgoing call i t i d b f il d ll Call Retry Disab Disab is retried on a busy or failed call attempt Dial Delay 1 4 5 6 10 1 4 5 6...

Page 14: ...gmt Modem IP Adr Edit Edit Specifies the IP address for the MODEM t h fi d f Modem IP Adr Clear Clear MODEM port when configured for Mgmt Mdm NetMask Edit Edit Specifies the Subnet Mask needed to acce...

Page 15: ...ate regulatory agencies and inspection authorities to ensure compliance 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in s...

Page 16: ...at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly appr...

Reviews: