background image

Copyright 

 1998 Paradyne Corporation.

All rights reserved.
Printed in U.S.A.

Notice

This publication is protected by federal copyright law. No part of this publication may be
copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated
into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties without the
express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, 
FL  33773.

Paradyne Corporation makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of merchantability or
fitness for a particular purpose. Further, Paradyne Corporation reserves the right to
revise this publication and to make changes from time to time in the contents hereof
without obligation of Paradyne Corporation to notify any person of such revision or
changes.

Changes and enhancements to the product and to the information herein will be
documented and issued as a new release to this manual.

Warranty, Sales, and Service Information

Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:

Via the Internet:  Visit the Paradyne World Wide Web site at
http://www.paradyne.com

Via Telephone:  Call our automated call system to receive current information via
fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A, call 1-727-530-2340

Document Feedback

We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to [email protected]. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.

Trademarks

All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.

 

Summary of Contents for ACCULINK 3163 DSU

Page 1: ...ACCULINK 3163 DSU CSU QUICK REFERENCE Document No 3163 A2 GL10 00...

Page 2: ...and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additio...

Page 3: ...ore installing the DSU CSU read the Important Safety Instructions beginning on page 13 Quick Start Procedure The following procedure is for experienced DSU CSU users who are familiar with the 3163 DSU...

Page 4: ...LEDs blink twice When the test is complete verify that the DSU CSU is functional by observing that the OK and NETWORK SIG LEDs are lit PORT 1 COM PORT MODEM POWER NETWORK CAUTION AUX PORT OR COM PORT...

Page 5: ...ar Near Cur 8Tot Intvl Load Edit Area From Choose Function Activ Cust1 Cust2 Fact1 Fact2 User Alarm NET Port Chan Gen Mgmt Gen Save Cust1 Activ Cust2 Edit Cnfig Prt1 Clear Dsply Ctrl Rel ClrReg Reset...

Page 6: ...B Port initiated Loopbacks allows L b k t b i iti t d th h Port LB DCLB DCLB Loopbacks to be initiated through the port by the external DTE Both Both y Disab Disab All Ones DTR DTR All ones sent to ne...

Page 7: ...ab Disab Specifies whether the FDL s Mgmt Link SNMP SNMP S ecifies whether the FDLs Management Link is enabled NET LLB Enab Enab Network initiated LLB allows LLB to NET LLB Disab Disab Network initiat...

Page 8: ...60 704 616 768 672 832 728 896 784 960 840 1024 896 1088 952 1152 1008 1216 1064 1280 1120 1344 1176 1408 1232 1472 1288 1536 1344 64 56 128 112 192 168 256 224 320 280 384 336 448 392 512 448 576 504...

Page 9: ...N21 D21 N22 D22 N23 D23 N24 D24 This configuration option appears if the Assigned By configuration option is Block or ACAMI Line 1 Displays Line 2 Displays Meaning Comments Description Unassigned N1 N...

Page 10: ...t Enab Enab Allows bypass of self test on Self Test Disab Disab Allows by ass of self test on initialization FP Access Enab Enab Controls whether front panel FP Access Disab Disab Controls whether fro...

Page 11: ...5 1 5 Selects the number of stop bits for the COM port Stop Bits 2 2 the COM port Ignore DTR Yes Yes Specifies whether the COM port Ignore DTR No No S ecifies whether the COM ort ignores DTR CmInActTm...

Page 12: ...ab Enab Specifies whether the modem port di t ft t i i d Modem Port Inactivity Timeout Disab Disab disconnects after a certain period of inactivity 5 5 MoDiscTm Modem Port Up Up Specifies the period o...

Page 13: ...arm messages on MODEM port Call Retry Enab Enab Specifies whether an outgoing call i t i d b f il d ll Call Retry Disab Disab is retried on a busy or failed call attempt Dial Delay 1 4 5 6 10 1 4 5 6...

Page 14: ...gmt Modem IP Adr Edit Edit Specifies the IP address for the MODEM t h fi d f Modem IP Adr Clear Clear MODEM port when configured for Mgmt Mdm NetMask Edit Edit Specifies the Subnet Mask needed to acce...

Page 15: ...ate regulatory agencies and inspection authorities to ensure compliance 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in s...

Page 16: ...at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly appr...

Reviews: