background image

 4

Configuration Options

Configuration options are accessed from the Cnfig branch of the front panel menu.

00-15571-01

CSU ESF

Rlpbk

Lpbk

Ptrns

Lamp

LLBUP LLBDN

Abort

Send

Mon

QRSS

1in8

PLB

DLB

RLB

LLB

Abort

Ctrl

Call

Rel

ClrReg

Reset

CID

Passwd

DL

Mon

EQPT NET

Stat

DevHS STest Perf TStat ENET

ID

User

Telco

Cur

24Tot

Intvl

Disc

Dial

Pass

ChDir

1 . . 5,A

(Directory)

1 . . 5,A

(Directory)

Load Edit Area From:

Activ

Cust1

Cust2

Fact1

Fact2

Choose Function:

Edit

Save

Cust1

Activ

Cust2

User

Alar

Gen

DTE

Mgmt

Gen

Trap

NET

Cnfig

Test

LED

Summary of Contents for ACCULINK 3150

Page 1: ...ACCULINK 3150 CSU QUICK REFERENCE Document No 3150 A2 GL11 80 ...

Page 2: ...Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Internet Visit the Paradyne World Wide Web site at www...

Page 3: ...fety Instructions beginning on pageNO TAG The following procedure is offered for experienced CSU users who are familiar with the 3150 CSU installation process and have no special requirements for their application Refer to the ACCULINK CSU Operator s Guide for more information 1 Attach the power cord to the rear of the CSU and the other end to a grounded 115 Vac power outlet 2 Attach the DTE cable...

Page 4: ...o display edit configuration options 1 From the top level menu screen which you can access by pressing the key select Cnfig 2 Select the configuration option set to be copied into the Edit area by using the appropriate Function key F1 F2 or F3 Use the scroll keys and if necessary The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appr...

Page 5: ...Front Panel 3150 CSU 3150 CSU 3150 CSU Serial Port or COM Port Network Port Modem Port COM Port Network Port Modem Port Network Port or SNMP Manager SNMP Manager PC or Terminal or Terminal 10 Base T Port POWER 10 BASE T COM DSX 1 MODEM NETWORK 10 Base T Port SNMP Manager 10BaseT Cabling Examples ...

Page 6: ...bort Send Mon QRSS 1in8 PLB DLB RLB LLB Abort Ctrl Call Rel ClrReg Reset CID Passwd DL Mon EQPT NET Stat DevHS STest Perf TStat ENET ID User T elco Cur 24T ot Intvl Disc Dial Pass ChDir 1 5 A Directory 1 5 A Directory Load Edit Area From Activ Cust1 Cust2 Fact1 Fact2 Choose Function Edit Save Cust1 Activ Cust2 User Alar Gen DTE Mgmt Gen Trap NET Cnfig Test LED ...

Page 7: ... AIS Enab Enab Sends AIS to the DTE on failure of the Send AIS Disab Disab Sends AIS to the DTE on failure of the Network interface signal Yellow Enab Enab Transcodes and sends Yellow signal to the DTE on receiving Yellow from the Yellow Disab Disab the DTE on receiving Yellow from the Network Table 2 Network Interface Configuration Options 1 of 2 Option Factory 1 Factory 2 Comments Description NE...

Page 8: ... network signal to the network interface on a failure of the DTE signal Yellow Enab Enab Transcodes and sends Yellow signal to the network on receiving Yellow from Yellow Disab Disab g the network on receiving Yellow from DTE Circuit Ident Edit Edit Specifies the transmission vendor s Circuit Ident Clear Clear Specifies the transmission vendor s circuit identifier CRC PThru Enab Enab Determines wh...

Page 9: ...ntil a password Password Modem Modem prevents access until a password is entered Both Both is entered Mgmt Mgmt Com Use ASCII ASCII Controls how the COM port is Com Use Daisy Daisy Controls how the COM port is used Term Term Com Type Async Async Specifies whether the COM port uses synchronous or Com Type Sync Sync uses synchronous or asynchronous operation Com Clk Int Int Controls whether the COM ...

Page 10: ...gmt Modem Use ASCII ASCII Specifies how the modem port is used Term Term used Modem Type Async Async Specifies whether the port uses synchronous or asynchronous Modem Type Sync Sync synchronous or asynchronous operation Modem Rate 1 2 1 2 Specifies the bit rate for the Modem Rate 2 4 2 4 Specifies the bit rate for the modem port in kbps MChar Len 7 7 Specifies the character length in MChar Len 8 8...

Page 11: ...IP address DefGatewayAdr Edit Edit Specifies the IP address where messages for other subnets are DefGatewayAdr Clear Clear p messages for other subnets are sent TnSession Enab Enab Specifies whether the DSU CSU responds to Telnet session TnSession Telnet Session Disab Disab p responds to Telnet session requests TnPaswd Enab Enab Specifies whether a password is TnPaswd Telnet Password Disab Disab S...

Page 12: ...fter a trap is sent DialOut Enab Enab Provides the option to allow automatic dial out to send alarm messages on DialOut Disab Disab p dial out to send alarm messages on MODEM port Call Retry Enab Enab Specifies whether an outgoing call is Call Retry Disab Disab Specifies whether an outgoing call is retried on a busy or failed call attempt Dial Delay 1 4 5 6 10 1 4 5 6 10 The time in minutes to del...

Page 13: ...ice System Location Edit Edit The SNMP system location for this System Location Clear Clear The SNMP system location for this device System Contact Edit Edit The SNMP system contact name System Contact Clear Clear The SNMP system contact name for this device CommunityName1 Edit Edit A community name that is allowed access to this device Defaults to CommunityName1 Clear Clear y access to this devic...

Page 14: ...NetMask Edit Edit Specifies the subnet mask for the modem port if Modem Use is set to Mdm NetMask Clear Clear p modem port if Modem Use is set to Mgmt Alt Mdm IP Adr Edit Edit Specifies the alternate IP address for the modem port if Modem Use Alt Mdm IP Adr Clear Clear p for the modem port if Modem Use is set to Mgmt Alt Mdm NetMask Edit Edit Specifies the alternate subnet mask for the modem port ...

Page 15: ...EDLn EDLn Disab Disab Gen Trap Warm Warm Specifies the general trap types to enable WarmStart Authentication Gen Trap Auth Auth p g p yp enable WarmStart Authentication Failure or both Both Both Failure or both Entp Trap Enab Enab Specifies whether the EnterpriseSpecific trap type is Entp Trap Disab Disab p EnterpriseSpecific trap type is enabled Disab Disab Link Trap Up Up Specifies the link trap...

Page 16: ... may be required by the regulatory inspection authority for the installation site are the responsibility of the customer 7 When installed in the final configuration the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure complia...

Page 17: ... Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in ...

Page 18: ...phone Company The CSU can be configured to support any of the following framing format and line signaling techniques The CSU s configuration must correspond to the T1 line s parameters The 3150 CSU s internal modem connects to the Public Switched Telephone Network using a USOC Type RJ11C jack The Facility Interface Code 02LS2 along with the RJ11C jack should be specified to the telephone company w...

Page 19: ... the company service center for repair contact them directly for return instructions using one of the following methods Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com Via Telephone Call our automated system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 If ...

Page 20: ...lterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in...

Reviews: