B-1
3360-A2-GB20-30
March 1999
Technical Specifications
Overview
B-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The technical specifications for the Models 3360,
3364, and 3365 NTUs are listed in Table B-1.
Table B-1
(1 of 2)
Models 3360/3364/3365 NTUs Technical Specifications
Specifications
Criteria
POWER REQUIREMENTS
Typical:
AC Power Module
Optional:
+24 Vdc
– 48 Vdc
– 48 Vdc Redundant
Refer to the labeling on the ac power module for input requirements
+20 Vdc to +32 Vdc, 0.75A
–38 Vdc to –60 Vdc, 0.375A
–38 Vdc to –60 Vdc, 0.375A
POWER CONSUMPTION AND
DISSIPATION
22.0 watts, 75.0 Btu per hour at 115 volts (ac power); 18.0 watts, 61.5 Btu per
hour at +24 and – 48 Vdc (dc power)
G.703 DTE INTERFACE
Physical Interface
Framing Format
Coding Format
BNC pair for 75-ohm coaxial cables (unbalanced) or
DB15 socket for 120-ohm twisted pair (balanced)
CRC-4, non-CRC-4
AMI, HDB3
HDSL NETWORK INTERFACE
Physical Interface
Framing Format
Coding Format
RJ48C for HDSL
CRC-4, non-CRC-4
HDB3
PORT INTERFACE
Standards
Rates
EIA-530-A, V.35, RS- 449, X.21
Nx64 kbps
B
Summary of Contents for ACCULIN 3364
Page 1: ...ACCULINK 3360 3364 AND 3365 E1 NTU OPERATOR S GUIDE Document No 3360 A2 GB20 30 March 1999 ...
Page 8: ...ACCULINK 3360 3364 and 3365 E1 NTU iv March 1999 3360 A2 GB20 30 ...
Page 16: ...ACCULINK 3360 3364 and 3365 E1 NTU 1 6 March 1999 3360 A2 GB20 30 ...
Page 26: ...ACCULINK 3360 3364 and 3365 E1 NTU 2 10 March 1999 3360 A2 GB20 30 ...
Page 64: ...ACCULINK 3360 3364 and 3365 E1 NTU 3 38 March 1999 3360 A2 GB20 30 ...
Page 92: ...ACCULINK 3360 3364 and 3365 E1 NTU A 2 March 1999 3360 A2 GB20 30 ...
Page 156: ...ACCULINK 3360 3364 and 3365 E1 NTU E 20 March 1999 3360 A2 GB20 30 ...
Page 162: ...ACCULINK 3360 3364 and 3365 E1 NTU H 2 March 1999 3360 A2 GB20 30 ...