Configuration Options
C-21
3360-A2-GB20-30
March 1999
Table C-10
(1 of 2)
SNMP Trap Configuration Options
Num Trap Mgrs: 1
Next 1 2 3 4 5 6 Prev
Number of Trap Managers. Specifies the number of SNMP trap managers that are to receive traps for this unit.
NOTE: You must configure an IP address for each trap manager that is to receive trap messages.
Trap
n IP Adr:
Next Edit Clear Prev
Trap
n IP Address. Specifies the IP address for each trap manager. This configuration option is repeated for all trap
managers supported by the unit.
Edit – Allows you to edit or display the IP address for Trap Manager
n.
Clear – Allows you to clear the IP address for Trap Manager
n. The IP address is set to 000.000.000.000.
Trap
n Dst: None
Next None Com Aux FDL EDL1 EDL2 EDL3 EDL4 Prev
Trap Manager
n Destination. Specifies the network destination for Trap Manager n. This configuration option is displayed
for the number of trap managers (
n) specified by the Number of Trap Managers configuration option.
None – No Trap Manage
n network destination. Traps are discarded.
Com – The Trap Manager
n network destination is the communication port. This selection only appears if the Com Use
configuration option is set to SNMP or Daisy.
Aux – The Trap Manager
n network destination is the auxiliary port. This selection only appears if the Aux Use
configuration option is set to SNMP or Daisy.
FDL – The Trap Manager
n network destination is the FDL management link. This selection only appears if the FDL
management link is enabled for SNMP.
EDL
n – The Trap Manager n network destination is the EDLn port (where n is 1– 4). This selection only appears if the
synchronous data port’s EDL management link is enabled for SNMP.
NOTE: If the chosen destination link is disabled or down, the traps are discarded. Return to this menu and choose
another destination.
Gen Trap: Both
Next Disab Warm Auth Both Prev
General Trap Types. Specifies the general trap types to enable. For more information, refer to the
SNMP Traps
section in
Chapter 4,
Maintenance.
Disab – Disables the sending of trap messages for warmStart and authenticationFailure events.
Warm – Sends trap messages for warmStart events to the currently configured trap manager(s).
Auth – Sends trap messages for authenticationFailure events to the currently configured trap manager(s).
Both – Sends trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).
NOTE: This configuration option is not available if the SNMP Trap configuration option (in the
Alarm Configuration
Options
section) is disabled.
Summary of Contents for ACCULIN 3364
Page 1: ...ACCULINK 3360 3364 AND 3365 E1 NTU OPERATOR S GUIDE Document No 3360 A2 GB20 30 March 1999 ...
Page 8: ...ACCULINK 3360 3364 and 3365 E1 NTU iv March 1999 3360 A2 GB20 30 ...
Page 16: ...ACCULINK 3360 3364 and 3365 E1 NTU 1 6 March 1999 3360 A2 GB20 30 ...
Page 26: ...ACCULINK 3360 3364 and 3365 E1 NTU 2 10 March 1999 3360 A2 GB20 30 ...
Page 64: ...ACCULINK 3360 3364 and 3365 E1 NTU 3 38 March 1999 3360 A2 GB20 30 ...
Page 92: ...ACCULINK 3360 3364 and 3365 E1 NTU A 2 March 1999 3360 A2 GB20 30 ...
Page 156: ...ACCULINK 3360 3364 and 3365 E1 NTU E 20 March 1999 3360 A2 GB20 30 ...
Page 162: ...ACCULINK 3360 3364 and 3365 E1 NTU H 2 March 1999 3360 A2 GB20 30 ...