MIB Descriptions
B-27
9161-A2-GH30-20
September 1997
Asynchronous Port Table
The Asynchronous Port Table contains an entry for the COM port when the port is
configured for asynchronous operation. The Asynchronous Port Table is not
supported for the synchronous data ports. This object is supported for the COM
port only. For this unit, entries in the table that are counters (rs232AsyncPortEntry
6–8) are used to collect statistics only and are not supported. Clarification for
objects contained in this table as it applies to the unit is provided below.
Object
Description
Setting/Contents
rs232AsyncPort
Bits
(rs232Async
PortEntry 2 )
Specifies the number of bits
in a character.
Supports only the following values:
7 – 7-bit characters. Only use when
Port Use is set to Alarm.
8 – 8-bit characters
rs232AsyncPort
StopBits
(rs232Async
PortEntry 3 )
Specifies the number of
stop bits supported.
Supports only the following values:
one(1) – One stop bit
two(2) – Two stop bits
one-and-half(3) – One and a half
stop bits
rs232AsyncPort
Parity
(rs232Async
PortEntry 4 )
Specifies the type of parity
used by the port.
Supports only the following values:
none(1) – No parity bit
odd2) – Odd parity
even(3) – Even parity
rs232AsyncPort
AutoBaud
(rs232Async
PortEntry 5 )
Specifies the ability to
automatically sense the
input speed of the port.
Supports only the following value:
disabled(2) – Does not support
Autobaud