9
7986-A2-GZ40-00
March 1999
Table 3.
System Options
DSL Mode
Possible Settings: LTU, NTU
Default Setting: NTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE:
Changing this option will reset the unit.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is
remotely managed, so that control can be regained after a test is accidentally executed.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
G.703 Line Termination
Possible Settings: 120 Ohm, 75 Ohm
Default Setting: 120 Ohm
Determines whether the line impedance is set for 75 Ohm or 120 Ohm.
Table 4.
Communication Port Options (1 of 2)
Port Use
Possible Settings: Terminal, Net Link
Default Setting: Terminal
Specifies how the communications port is to be used.
Port Type
Possible Settings: Asynchronous, Synchronous
Default Setting: Asynchronous
When Port Use is set to Net Link, Port Type controls whether the communication port
will be asynchronous or synchronous.
Data Rate
Possible Settings: 9.6, 14.4, 19.2, 28.8, 38.4
Default Setting: 9.6
Specifies the communication port baud rate.
Character Length (Terminal Use Only)
Possible Settings: 7, 8
Default Setting: 8
Determines the character length of the communication port.