7984-A2-GZ40-00

February 1999

Configuration Edit/Display

The Configuration Edit/Display screen is displayed when the current, customer,
or default configuration is loaded. To access the Configuration Edit/Display
screen, follow this menu selection sequence:

Main Menu

Configuration 

Current Configuration

– or –

Main Menu

Configuration 

Default Factory Configuration

Î

ÎÎ

main/config/edit

    Hotwire

Model: 7984

CONFIGURATION EDIT/DISPLAY

Network

DSX-1

System Options

Communication Port

Management and Communication

–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions, ESC for previous menu

MainMenu

Exit

 Save

Select . . .

To Access the . . .

To Configure the . . .

Network

Network Interface Options, Table 1

DSL network interfaces on
the unit.

DSX-1

DSX-1 Interface Options, Table 2

DSX interface.

System Options

System Options, Table 3

General system options of
the unit.

Communication
Port

Communication Port, Table 4

Unit’s COM port options.

Management
and
Communication

Telnet Session Options, Table 5

Communication Protocol Options, 
Table 6

General SNMP Management
Options, Table 7

SNMP NMS Security Options, 
Table 8

SNMP Traps Options, Table 9

Management support of the
unit through SNMP and
Telnet.

Summary of Contents for 7984

Page 1: ...SL MVL Systems Select the following document 7984 A2 GB20 Hotwire 7984 M HDSL Standalone Termination Unit with DSX 1 Interface User s Guide To request a paper copy of a Paradyne document Within the U...

Page 2: ...ct the unit to an external 48 Vdc power source as described in the documentation shipped with the power supply and power cable Connecting the Unit to an Optional External 24 Vdc Power Source Using the...

Page 3: ...onnecting to a System Terminal An optional system maintenance terminal may be attached to your Hotwire 7984 Standalone Termination Unit through the modular jack on the rear panel The system maintenanc...

Page 4: ...a 2 port Hotwire 8784 M HDSL Termination Unit in a central office CO In this configuration a frame relay switch and a router are connected through the termination unit to partner units supporting a ho...

Page 5: ...an NTU If you are using this unit as an NTU the configuration options may not need to be altered The 7984 Standalone Termination Unit has two sets of configuration option settings The Current Configur...

Page 6: ...Management and Communication Ctrl a to access these functions ESC for previous menu MainMenu Exit Save Select To Access the To Configure the Network Network Interface Options Table 1 DSL network inte...

Page 7: ...djusts to the best line rate for conditions or is fixed at the rate in the DSL Line Rate field AutoRate is only available when the unit is configured as an LTU DSL Line Rate Possible Settings 400 528...

Page 8: ...ensates for signal distortion for a DSX 1 signal over a given cable length in feet Send AIS on Network Failure Possible Settings Enable Disable Default Setting Enable Specifies the action taken on the...

Page 9: ...e Settings Enable Disable Default Setting Enable Determines if the unit will respond to Telco loopback commands on the DSX 1 interface Remote Telco Loopback Possible Settings Enable Disable Default Se...

Page 10: ...Terminal Use Only Possible Settings Enable Disable Default Setting Disable Specifies if an ID and password are required to access the asynchronous terminal interface on the communication port Login I...

Page 11: ...to access to the ATI through a Telnet session Login IDs are created with a password and access level Session Access Level Possible Settings Administrator Operator Default Setting Administrator The Te...

Page 12: ...unication Port IP Address when the unit is configured as a network communication link Communication Port IP Address is only used when the Port Use option on the Communication Port Options menu is set...

Page 13: ...rnal SNMP manager when that manager attempts to access an object in the MIB Name 1 Access Possible Settings Read Read Write Default Setting Read Determines the access level for Community Name 1 Commun...

Page 14: ...ssible Settings 1 2 3 4 5 6 7 8 9 10 Default Setting 1 Specifies the number of SNMP management systems that can send SNMP messages NMS n IP Address Possible Settings 000 000 000 000 223 255 255 255 Cl...

Page 15: ...ble Settings DSL COM Default Setting DSL Provides the network destination path of each trap manager General Traps Possible Settings Disable Warm AuthFail Both Default Setting Both Determines which SNM...

Page 16: ...he proper static control precautions contact your nearest sales or service representative Procedure To configure the unit using internal Switchpacks S1 and S2 1 Power down the unit and disconnect the...

Page 17: ...99 Switchpack Locations Use the following illustration to locate Switchpacks S1 and S2 98 16073a Switchpack S1 S2 Front S2 Rear S1 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 Hotwire 7984 Standalone Termina...

Page 18: ...acks Enabled 2 Not used 3 Select the unit s primary timing source Only valid for units configured as LTU OFF Internal Clock ON External Clock 4 Control the unit s T1 line coding OFF B8ZS ON AMI 5 Cont...

Page 19: ...pported OFF Enabled ON Disabled 7 Control whether remote Telco loopbacks are supported OFF Disabled ON Enable 8 Switch between two versions of firmware The 7984 has two banks of flash memory used to h...

Page 20: ...provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer 7 When installed in the final co...

Page 21: ...made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation WARNING To Users of Digital Apparatus in Canada This Class A digital apparatus meets all requi...

Page 22: ...nister Logins Download Code Apply Download Reset Device Network and DSX 1 Test Device Tests Abort All Tests 99 16113 01 Network DSX 1 Network Error Statistics Network Performance Statistics DSX 1 Stat...

Reviews: