Testing
5-2
7520-A2-GB20-20
May 1998
Loopbacks can be started from a variety of points in the network, as shown in
Table 5-1.
Table 5-1.
Device Messages
Loopback Type
Initiated By
Notes
Bilateral Loopback
User
Remote unit sending
V.54 sequence
When enabled, running a DSU loopback
also automatically starts a local
loopback. Refer to Table A-3,
Data Port
Options
, to enable.
CSU Loopback
User (Network tests)
DDS Network, by
loop current reversal
When initiated by the network, CSU
Loopback cannot be disabled by the
user.
DSU Loopback
(Digital)
User (Network tests)
DDS Network
When initiated by the network, DSU
Loopback cannot be disabled by the
user.
Local Loopback
User
DTE via CT141
Control via CT141 can be disabled.
Refer to Table A-3,
Data Port Options
.
Network-initiated
2.4 – 56 kbps DSU
Loopback (Non-
latching loopback)
DDS Network
Cannot be disabled by user.
Network-initiated
64 kbps CC DSU
Loopback
(Latching loopback)
DDS Network
Includes optional data scrambling and
uses 25-second timer to detect the
network sequence. Can be disabled by
user. Refer to Table A-2,
Network
Interface Options
.
Remote Digital
Loopback
Remote unit sending
V.54 sequence
Same as a DSU Loopback but initiated
by a remote unit via V.54 sequence.
Can be disabled locally. Refer to
Table A-2,
Network Interface Options
.
V.54 Sequences to
remote unit
User
DTE via CT140
Control via CT140 can be disabled.
Refer to Table A-3,
Data Port Options
.
Summary of Contents for 7520
Page 1: ...MODEL 7520 DSU USER S GUIDE Document No 7520 A2 GB20 20 May 1998...
Page 6: ...Contents iv 7520 A2 GB20 20 May 1998 This page intentionally left blank...
Page 24: ...Customizing the DSU 3 4 7520 A2 GB20 20 May 1998 This page intentionally left blank...
Page 36: ...Monitoring the DSU 4 12 7520 A2 GB20 20 May 1998 This page intentionally left blank...