16
Data Ports
Select Data Ports, then Physical to configure physical characteristics for the user data
port, which is connected to a DTE.
Time Slot Assignment
Select Sync Data Port Assignments under the Time Slot Assignment configuration
branch to assign DS0s on the T1 network interface.
Node IP (Management and Communication Options)
Select Node IP to configure support of the IP communication network.
Data Ports
Configuration Option
Settings
Default in [Bold]
Port Base Rate (Kbps)
[Nx64], Nx56
Invert Transmit Clock
[Auto], Enable, Disable
Transmit Clock Source
[Internal], External
Monitor RTS (Control)
[Enable], Disable
Monitor DTR
[Enable], Disable
Port (DTE) Initiated Loopback
[Disable], Local
Network Initiated Data Channel
Loopback
[Disable], V.54, ANSI_FT1, V.54_&_ANSI
Sync Data Port-to-Network Interface Time Slot Assignment
Network Channel
Settings
Default in [Bold]
N01–N24
[Available], Port1
Node IP
Configuration Option
Settings
Default in [Bold]
Node IP Address
001.000.000.000–223.255.255.255,
[Clear]
Node Subnet Mask
[000.000.000.000]–255.255.255.255, Clear
Default IP Destination
[None], COM, Ethernet