 5

7112-A2-GN10-40

February 2000

NOTE:

The Pin 17 to Pin 24 crossovers shown in Figure 1 are not required and have
no effect with the Model 7112.

Pin 1

Pin 14

Pin 13

Pin 25

Pin 1

Pin 14

Pin 13

Pin 25

P2

Plug

Chassis Ground

TXD

RXD

RTS

CTS

DSR

Signal Ground

CD (RLSD)

TXC

RXC

DTR

XTXC

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Pin

98-15811

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

P1

Chassis Ground

TXD

RXD

RTS

CTS

DSR

Signal Ground

CD (RLSD)

TXC

RXC

DTR

XTXC

Pin

P2

P1

Plug

Figure 1.

Serial Crossover Cable for External Modem

Summary of Contents for 7112

Page 1: ...n for this product is available at www paradyne com Select Library Technical Manuals Subrate Digital Access Devices Select the following document 7112 A2 GB20 Model 7112 T1 DSU CSU with Internal Ether...

Page 2: ...other end A DCE with a V 35 connector to the DTE port Standard V 35 crossover cable with MS34 plug connectors on both ends Contact your sales or service representative to order these cables For cable...

Page 3: ...e DSU CSU 1 Plug the 8 pin connector on the RJ48C network cable into the NETWORK connector on the DSU CSU 2 Plug the other end of the RJ48C network cable into the RJ48C modular jack 3 Plug one end of...

Page 4: ...l or PC 1 Use a standard serial crossover cable as shown in Figure 1 on the next page 2 Enable auto answer on your modem and configure it to use standard RS 232 detection and control for LSD DSR and D...

Page 5: ...Pin 13 Pin 25 P2 Plug Chassis Ground TXD RXD RTS CTS DSR Signal Ground CD RLSD TXC RXC DTR XTXC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pin 98 15811 1 2 3 4 5 6 7 8 9 10 11 1...

Page 6: ...is displayed on the ASCII terminal or PC Press the Enter key Verify that the Main Menu appears main Access Level 1 PARADYNE Device Name Model 7112 MAIN MENU Status Test Configuration Control Ctrl a t...

Page 7: ...ing Determine if you want SNMP traps generated Refer to Chapter 8 Messages and Troubleshooting Change configuration option settings Refer to Appendix A Configuration Option Tables and Appendix B Works...

Page 8: ...e ANSI Performance Report Messages Disable Enable Circuit Identifier Blank Table 4 Cross Connect Assignments Configuration Option Settings default in Bold Assign By Block ACAMI Channel Synchronous Dat...

Page 9: ...gs default in Bold Data Rate Kbps 2 4 4 8 9 6 14 4 19 2 28 8 38 4 Character Length 7 8 Parity None Even Odd Stop Bits 1 2 Monitor DTR Enable Disable Login Required Enable Disable Port Access Level Lev...

Page 10: ...Security NMS IP Validation Enable Disable Number of Managers 1 2 3 4 5 6 7 8 9 10 NMS n IP Address 000 000 000 000 255 255 255 255 Access Level Read Read Write SNMP Traps SNMP Traps Enable Disable Nu...

Page 11: ...ulatory agencies and inspection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate...

Page 12: ...rence to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own e...

Page 13: ...CC compliant telephone cord and modular plug is provided with this equipment This equipment is designed to be connected to the telephone network or premises wiring using a compatible jack which is Par...

Page 14: ...c water pipe system if present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should conta...

Reviews: