background image

TM40 Quick Install Guide

Printed in Canada | 09/2011

4.

Secure the front housing assembly to the back plate by 
snapping it into place.

The installation process is complete.

TM40 to Panel Connections

As shown in the 

Wiring Diagram

, the red, black, green, and yellow 

wires on the TM40 must be connected to their corresponding 
labeled terminals on the control panel’s PCB. The blue wire is 
connected to either a keypad zone or external temperature 
sensor.

Wiring Diagram

Technical Specifications

Power Input

9 to 16 Vdc

Consumption

110 mA

Display

16-bit, color LCD; 5.4 x 9.5 cm (2.1 x 3.7 in.)

Resolution

480 x 272 pixels

Dimensions

12.4 x 8.1 x 1.6 cm (4.9 x 3.2 x 0.7 in.)

Weight

0.15 kg (0.33 lbs.)

Humidity

5-90%

Sensors

Indoor temperature sensor

Standards

Complies with EN 50131 Security Grade 3 Class II

CONTROL PANEL

BLUE

ZONE/TEMP

RED

BLK

GRN

YEL

Kpd 1 or Kpd 2

N.C

.

COM

AUX- GRN YEL

AUX+

Warranty

: For complete warranty information on this product, please 

refer to the Limited Warranty Statement found on the Web site 
www.paradox.com/terms. Your use of the Paradox product signifies your 
acceptance of all warranty terms and conditions.
© 2011 Paradox Ltd. All rights reserved. Specifications may change 
without prior notice. 

www.paradox.com

Reviews: