20 Installation and Operating Instructions
previously been programmed with a PIN/card.
If the red LED is ON, the user code is free.
5. Press the
[
CLEAR
]
key.
The red LED flashes.
6. Press the
[
ENTER
]
key to confirm the removal
and advance to the next section.
To exit:
• Press
[
CLEAR
]
key. The red and green LEDs
will flash alternately.
• Press the
[
CLEAR
]
key a second time. Both
LEDs will flash simultaneously.
• Press and hold the
[
CLEAR
]
key a third time
to exit this section.
SECTION [204] USER CODE RESET
User Code Reset is used to delete all the User
Codes (from User Code
000
to
999
).
To Reset all User Codes:
1. Press and hold the
[
CLEAR
]
key for 4 seconds.
The reader emits a confirmation beep, the
green LED turns ON and the red LED turns
OFF.
2. Enter
[
MASTER
CODE
1
or
MASTER
CODE
2]
and
press the
[
ENTER
]
key.
Reader emits a confirmation beep and the red
and the green LEDs flash simultaneously.
3. Enter
[204]
and press the
[
ENTER
]
key.
Reader emits a confirmation beep, the green
LED turns ON and the red LED turns OFF.
4. Press the
[1]
key and then press the
[
ENTER
]
key to confirm the reset.