SYSTEM PROGRAMMING
The Installer Code (default: 000000) can
program a new Installer Code PIN in section
[200]
and program all the system sections from
[001]
to
[005]
and
[101]
to
[104]
.
To Enter System Programming Mode:
1. Press and hold the
[
CLEAR
]
key for 4 seconds.
The reader emits a confirmation beep, the
green LED turns ON and the red LED turns
OFF.
2. Enter the
[
INSTALLER
CODE
]
and press the
[
ENTER
]
key.
Reader emits a confirmation beep and the
green LED flashes.
3. Enter the 3-digit
[
SECTION
]
and press the
[
ENTER
]
key.
Reader emits a confirmation beep and green
LED becomes constant.
4. Enter the required
[
DATA
]
and press the
[
ENTER
]
key.
The reader emits a confirmation beep and the
green LED flashes.
Note:
It may take several seconds for the
module to register the command and emit a
confirmation beep.
5.
To program another section, repeat steps
3 and 4
. To exit, press and hold the
[
CLEAR
]
key for 4 seconds.
The reader emits a rejection beep and the
green LED turns OFF.