IPR512: IP Monitoring Receiver
1 of 8
Quick Start
IPR512: IP Monitoring Receiver
Getting Started
The following instructions explain the basic connections and programming required to get your Paradox IP Monitoring
Receiver up and running. They also guide the installer on how to register the Paradox reporting module (IP100 Internet
Module or PCS100 Communicator Module - GPRS Edition) to the receiver. For more detailed information, please refer to
the IPR512 Operations Manual.
Figure 1: System Overview
Step 1: Connect COM1
(Automation Software)
Connect the receiver to a PC running the Automation Software. Connect the provided 3m (10ft) DB25 to DB9 cable
between the receiver’s COM1 connector and a COM port on the PC, or on the PC’s serial hub.
Step 2: Connect COM2
(Optional: Serial printer/PC)
This step is optional. Connect the receiver to a serial printer or to a PC running
RS232 serial communication software
. The
receiver sends reported events in plain text format through COM2 (RS-232), which can be printed or viewed. Connect a
serial cable between the receiver’s COM2 (DB9) connector and a COM port on the serial printer or PC (gender changer is
included).
Out of the Box (included):
Additional Items Required (not included)
•
Paradox IP Monitoring Receiver (IPR512)
•
1GB memory card
•
1.8m (6ft) power cable
•
3m (10ft) DB25 to DB9 serial cable for COM1
•
DB9 gender changer
•
Rack-mount kit (brackets and screws)
•
Desktop installation kit (rubber feet)
•
Removable connector for Input/Output Relay
•
CAT5 network cable for LAN and WAN1/WAN2
•
Optional: DB9 or DB25 serial cable (RS-232) for COM2
•
Router and computer on a network to access internal web
page interface (LAN)
•
Router on a network with internet access (WAN1) to receive
control panel report codes
Serial
LAN
WAN1
WAN2
COM1
COM2
Paradox Control
Panel
Paradox Internet
Module (IP100)
Paradox IP Monitoring
Receiver (IPR512)
Automation
Software
Serial printer/
PC
Router
Routers
Web Page
Interface
Paradox Communicator Module -
GPRS Edition (PCS100)
COM
1
(PC)
COM
2
(SERIAL OUT)
LAN
WAN
1
WAN
2
INPUT
TRIGGER
C
1 COM NO
OUTPUT
RELAY
I
O
P A R A D O X . C O M
Automation
Software
COM
1
(PC)
COM
2
(SERIAL OUT)
LAN
WAN
1
WAN
2
INPUT
TRIGGER
C
1 COM NO
OUTPUT
RELAY
I
O
P A R A D O X . C O M
Serial printer/
PC