DigiplexNE Grafica Keypad Module 9
n
3.0 PROGRAMMING
Enter the Module Programming Mode, enter the desired section
followed by the required data. When programming the Grafica, use
the keypad’s
programming sheets (in the
DigiplexNE Modules’
Programming Guide
). Refer to “Programming Sections” in section
5.0 to keep track of which sections were programmed and how. We
strongly recommend you read this entire manual before you begin
programming.
Grafica can also be programmed using the
WinLoad
Security
System Management Software. For more information, refer to the
WinLoad instructions or visit our Web site at www.paradox.ca.
Floor plans, tunes and graphics can be downloaded to
Grafica using Winload V2.2 or higher and NEware V2.0 or
higher.
3.1 ENTERING MODULE PROGRAMMING MODE
Like all other keypads in the system, Grafica is programmed through
the control panel. To do so, you must first enter the Module
Programming Mode:
Step 1:
From Normal Mode press and hold the
[0]
key.
Step 2:
Enter the
[
INSTALLER
CODE
]
(by default 000000).
Step 3:
Enter section
[4003]
.
Step 4:
Enter Grafica’s 8-digit
[
SERIAL
NUMBER
]
.
Step 5:
Enter the 3-digit
[
SECTION
]
you want to program.
Step 6:
Enter the required
[
DATA
]
.
The control panel will then redirect all programming to the selected
Grafica keypad. Use the scroll and action keys to navigate through
desired sections.