background image

Installation Manual

P

R

D

O

X

P

R

D

O

X

S E C U R I T Y

S Y S T E M S

S E C U R I T Y

S Y S T E M S

VERSION 3.10

ESPRIT

738

EXPRESS

and

738

IM738-738EX 980324-0003

U

LISTED

Summary of Contents for Esprit 738

Page 1: ...Installation Manual P R D O X P R D O X S E C U R I T Y S Y S T E M S S E C U R I T Y S Y S T E M S VERSION 3 10 ESPRIT 738 EXPRESS and 738 IM738 738EX 980324 0003 U LISTED...

Page 2: ...E ALARM application refer to NFPA Standard 74 for details on locating smoke detectors There must be at least one UL Listed Indoor Fire Alarm Warning Signaling Appliance 3 For U L Burglar Applications...

Page 3: ...nsumption 6 BASIC INSTALLATION 6 11 LOCATION AND MOUNTING 6 EARTH GROUND 7 AC 7 PROGRAMMABLE OUTPUTS 7 BELL SIREN OUTPUT 7 AUXILIARY POWER TERMINALS 7 KEYPAD CONNECTIONS 8 ZONE INPUT TERMINALS 8 Singl...

Page 4: ...7 21 Feature select programming 17 Code priority 17 TLM options 17 Arming using PS1 keyswitch 18 Call back 18 Auto arm 18 Touch tone options 18 Partitioning 18 Silent alarm 18 Dialing pulse rates 18 R...

Page 5: ...Arming 25 Fast Exit 25 System Disarming 25 Alarm Memory 25 SYSTEM PARTITIONING 25 27 Partitioning 25 Arming Disarming 26 Keyswitch push button arming disarming PS1 27 ZONE BYPASSING 27 Bypass Recall...

Page 6: ...40 less components than any previous generations Total Compatibility All programming comprehensive system features and upload download software of Esprit panels are identical This total compatibility...

Page 7: ...ime reduces installation costs Alarm Relay optional on the 738 EXPRESS Single pole double throw dry contacts rated at 5 amps that follow the local alarm bell siren output SPECIFICATIONS Inputs and Out...

Page 8: ...or PS1 Current Consumption measured with battery connected without AC and with 1KW resistor on bell and 1KW resistor on zones 738 Express control panel 40mA DC 633 LED keypad 15mA DC Typical 738 cont...

Page 9: ...put is microprocessor controlled and will automatically shut down if current exceeds 3 amps The processor will allow current to resume as soon as another alarm is triggered The correct polarity connec...

Page 10: ...ds To disable the keypad zone when keypad zone supervision is deactivated 616 626 Connect the blue wire ZONE to the black wire COM and remove EOL jumper 2 633 639 640 Connect a 1kW resistor between th...

Page 11: ...code Advanced Technology Zone Connections 2 zones input 2 ZONES connection without EOL resistor N C contacts 738 only address 088 key MEM on key 10 off key 11 off address 090 key 8 on Each zone transm...

Page 12: ...ogrammed at addresses 472 478 and 510 FIRE CIRCUIT The fire zone enabled by defining zone 3 as 24 hour should always be connected with a 1KW W EOL resistor PN201100200 PRT on UL systems If there is a...

Page 13: ...conducts dynamic battery test under load every 60 seconds If the battery is disconnected or capacity is low trouble indicator key 1 illuminates Key 1 also comes on if battery voltage drops to 10 5 vo...

Page 14: ...he Answering Machine Override key 2ND or key 1 or determines the period of time between first and second call The second digit entered determines the number of rings required before the panel will ans...

Page 15: ...ccount numbers To program account codes for System A and B press ENTER installer code 7 10 8 The first four digits entered after this sequence correspond to the System A account code and the last four...

Page 16: ...ns to its original state N O once the conditions that triggered it have terminated Regular N C Solid state switch opens circuits from ground upon an event or events and returns to its original state N...

Page 17: ...he specified time pro grammed at addresses 044 045 and or once the no movement delay has elapsed address 055 To program auto arming go to address 086 and enable key 5 auto arm on time and or key 6 aut...

Page 18: ...in active following a specified event Auto test report options Reports the code programmed at address 512 after the number of days programmed at address 046 at the time programmed at addresses 047 048...

Page 19: ...System Options Default off for addresses 062 126 Feature select programming ON OFF status of the key lights determines feature selection In programming mode enter 3 digit memory address 062 to 126 To...

Page 20: ...dialing can be programmed If pulse is chosen for a central station phone number tone dialing can be programmed for the other number BYP switch from pulse to tone should be entered in the second phone...

Page 21: ...d restoration reports is sent to Telephone 1 until the system is disarmed When there is an alarm any ongoing communication upload download or reporting to Telephone 2 will immediately be stopped and t...

Page 22: ...ame as audible operation except that bell siren output will be pulsed intermittent on off One key arming enable Address 088 Key 7 on Pushing key 10 for 2 seconds full arms system Key 8 on Pushing key...

Page 23: ...on a keypad This sends a silent alert if a user is forced to disarm the system Only user 48 can use this feature Keypad zone supervision Keypad 1 zone supervision Kpd 1 Keypad 2 zone supervision Kpd...

Page 24: ...e the system is armed There is no entry delay Follow Addresses 108 110 Follow zones key on are instant zones that switch to delay definition during entry delay Delay 2 Addresses 112 114 One of two dif...

Page 25: ...t the 738 has 14 shutdown zones and the 738 EXPRESS has only 9 shutdown zones See the Programming Guides for the 738 and 738 EXPRESS Tamper trouble codes Addresses 472 495 SECTION 54 59 These codes id...

Page 26: ...armed light will illuminate followed by the keypad CONF beep If the access code is entered incorrectly the END REJ beep will sound If an incorrect entry is made at any time press CLEAR and re enter t...

Page 27: ...mory light MEM on your keypad will illuminate if any alarm situations took place while your system was armed A record of all alarm situations that occurred is stored in memory After disarming the syst...

Page 28: ...ed i e only System A or B is armed entering this code will arm the other system The code can be used to selectively arm disarm System A or System B zones Enter 11 code to arm disarm System A zones Ent...

Page 29: ...signed to the other system cannot be bypassed if the system is armed Bypass Recall This feature permits system users to reinstate the latest zone bypass instructions saved in memory By pressing BYP wh...

Page 30: ...put After opening the short or reducing the load power will be automatically restored to the auxiliary output after battery test has been conducted within 60 seconds Key 7 Communicator report failure...

Page 31: ...munication attempts master code and user 1 can only stop calls to Espload Until next reportable event installer code all communications When communicating with Espload it is impossible to enter progra...

Page 32: ...rogramming mode press CLEAR STREAMLINED PROGRAMMING Used to program sections 00 to 67 1 Press ENTER installer code 7 2 Key ENTER and 2ND will flash 3 Enter 2 digit section number 00 67 4 Enter 8 digit...

Page 33: ...All user code priorities can be programmed at addresses 062 to 066 068 to 072 and 074 to 078 with the installer code Note 2ND key flashes if location is empty To erase a code 1 Press ENTER 2 Enter mas...

Page 34: ...cations to maintain uninterrupted service GENERAL This equipment shall not be used on coin telephone lines Connection to party line service is subject to state tariffs RINGER EQUIVALENCE NUMBER REN Th...

Page 35: ...STRICTIONS CONCERNANT LE RACCORDEMENT DE MAT RIEL L tiquette d Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme certaines normes de protection d exp...

Page 36: ...ntellizone 17 22 Key access programming 29 Keypad 6 8 11 Keypad zone supervision 21 Keyswitch PS1 18 27 Late to close 15 Location and mounting 6 Mute 27 No movement 15 16 Operating modes 5 Panel answe...

Reviews: