FEATURE SELECT PROGRAMMING

Addresses 062 to 126 are programmed using the Feature Select Programming method. In this method, every key on the
keypad in each address represents an option or feature. Pressing a key will display it on the keypad and pressing it again
will extinguish the key. The On/Off status of each key determines the selected feature. To program using the Feature Select
Programming method:

1) Press 

[

ENTER

]

Installer Code (Default: 737373)

2) The [

ENTER

] key will flash to indicate you are in programming mode

3) Enter 

3-digit address

(062-126)

4) After entering the address, the keypad will display the feature selection status. Turn the keys On/Off by pressing the

appropriate key until the desired options are set. Then press the 

[

ENTER

]

key to accept, there will be a confirmation

"beep" indicating the options have been accepted. The [

ENTER

] key will flash to indicate that the software is awaiting the

next address entry

5) Return to 

step 3

to continue programming or press 

[

CLEAR

]

to exit programming mode

Addresses 

080

to 

085

for future use.

8

Summary of Contents for Esprit 738 Express+

Page 1: ...ramming The addresses 000 043 and 300 527 programmed in the Hexa Programming method are grouped into 67 sections where each section contains four addresses i e section 00 addresses 000 003 Using this...

Page 2: ...02 __ __ __ __ __ __ __ __ 03 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CENTRAL STATION TELEPHONE NUMBER 1 View at addresses 016 to 023 04 __ __ __ __ __ __ __ __ 05 __ __ __ __...

Page 3: ...3...

Page 4: ...programmable codes For single digit reporting enter skip 2ND as first digit Default empty 2ND 2ND If CONTACT I D format all codes is selected addresses 300 to 527 sections 11 67 do not have to be prog...

Page 5: ...REPORTING CODES reset code empty 5...

Page 6: ...REPORTING CODES reset code empty 6...

Page 7: ...__ ___ ___ seconds Exit delay factory default 60 seconds 050 ___ ___ ___ seconds Entry delay 1 factory default 45 seconds 051 ___ ___ ___ seconds Entry delay 2 factory default 45 seconds 052 ___ ___ _...

Page 8: ...staller Code Default 737373 2 The ENTER key will flash to indicate you are in programming mode 3 Enter 3 digit address 062 126 4 After entering the address the keypad will display the feature selectio...

Page 9: ...9...

Page 10: ...es Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes MEM Panel time and clear trouble 8 all 3 codes Key MEM flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes BY...

Page 11: ...itions SINGLE ZONE CONNECTIONS N C Contacts Without EOL Resistor N C Contacts With EOL Resistor UL ULC N O Contacts With EOL Resistor UL ULC N C Contacts Without EOL Resistor With Tamper Recognition N...

Page 12: ...KEYPAD ZONE CONNECTION DIAGRAMS Note Keypad zones always use 1K OHM EOL resistor 12...