DECIMAL PROGRAMMING
1) Press
[
ENTER
] + Installer Code (Default: 737373)
2) The [
ENTER
] key will flash to indicate you are in programming mode
3) Enter
3-digit address
(044-061)
4) The keypad will now display the current 3-digit data currently saved at
this address as described in figure 3
5) Enter
3-digit data
(000-255) value; after entering data you do not need
to press
[
ENTER
]
, the software will automatically save the data into the
selected address
6) Return to
step 2
or press
[
CLEAR
]
to exit programming mode
044:
___/___/___ (hours) Auto arm time (between "000" and "023")
045:
___/___/___ (minutes) Auto arm time (between "000" and "059")
046:
___/___/___ (days) Auto test report every ? days (between "001"
and "255") (000 = disabled)
047:
___/___/___ (hours) Auto test report (between "000" and "023")
048:
___/___/___ (minutes) Auto test report (between "000" and "059")
049:
___/___/___ (seconds) Exit delay
(factory default 60 seconds)
050:
___/___/___ (seconds) Entry delay 1
(factory default 45 seconds)
051:
___/___/___ (seconds) Entry delay 2
(factory default 45 seconds)
052:
___/___/___ (minutes) Bell cut-off time
(factory default 5 minutes)
053:
___/___/___ ( x 15 mSec.) Zone speed
(factory default 600 mSec.)
054:
___/___/___ (minutes) Power failure report delay
(factory default 30 minutes)
(000 = disabled)
055:
___/___/___ ( x 15 minutes) "No movement" report time
(factory default 8 hours)
(000 = disabled)
056:
___/___/___ PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes)
(factory default 5 seconds)
Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 + 128 = 133)
057:
___/___/___ Intellizone delay (in seconds, minimum = 10 seconds)
(factory default 48 seconds)
058:
___/___/___ Installer code lock (147 = locked, 000 = unlocked)
059:
___/___/___ (seconds) Programmable delay before alarm transmission (5 to 63 seconds) (000 = disabled)
060:
___/___/___ (seconds) Recent closing delay (000 = disabled)
061:
___/___/___ Future Use
7