background image

7

User functions

Normal function:

Type

Action

Display on 636 keypad

Arming / Disarm

[Enter 4 digit user code]

ARM is ON

Stay arming
(Stay zone will be bypassed)

[STAY][4 digit user code]

ARM & STAY are ON

Force arming
(Zone opened will be
bypassed, it consider arm
when it closed back)

[FORCE][4 digit user code]

ARM is ON

Instant arming
(Delay zone becomes Instant)

[STAY][4 digit user code], during the exit
delay, hold [STAY] for 3 seconds

ARM & STAY are ON

Bypass

[BYP][4 digit user code][ON the button
corresponding to the zone], then [ENTER].

BYP is ON

To Reset smoke detector after
an alarm on zone 3

Press [CLEAR] and [ENTER] together

Default master code is [4747] or [474747]

Important note:

Stay zone features MUST enable in [Step 1], or else it will not function

One-Touch Arming:

One-touch REGULAR arming

Press & hold the [key 0/10] button for 3 seconds

One-touch STAY arming

Press & hold the [key 11/STAY] button for 3 seconds

One-touch INSTANT arming

Press & hold the [key 11/STAY] button for 3 seconds, then again Press
& hold again the [key 11/STAY] button for 3 seconds

Panic function:

Press [1] & [3] at the same time, for AUDIBLE POLICE PANIC alarm.
Press [4] & [6] at the same time, for AUDIBLE MEDICAL alarm.
Press [7] & [9] at the same time, for FIRE alarm.

Change Master / create new user code:

Press [ENTER] [Master code – 4747] [ 2 digit section, 00 for master, 01 for user 1, 02 for user 2…], then
[4 digits new code][ENTER][ENTER]

E.g.:

[ENTER][4747][00] [5678][ENTER][ENTER], where 00 is master user and 5678 is the new master code.
[ENTER][5678][02] [2222][ENTER][ENTER], where 02 is user 2 and 2222 is the new user code.
[ENTER][5678][48] [5354][ENTER][ENTER], where 48 is user 48 and 5354 is the Duress code.

To delete user number

:

Press [ENTER] [Master code – 4747] [ 2 digit section, 02 for user 2, 03 for user 3…] [press
2ND][ENTER][CLEAR]

E.g.:

[ENTER][4747][02][Press 2ND][ENTER][CLEAR], user 2 is deleted.

Summary of Contents for ESPRIT 728 ULT

Page 1: ...es that are not selected in 100 to 108 automatically become delay zone key in 096 ON key wants to be SILENT zone key in 116 ON key wants to be STAY zone key in 124 ON all zone to allow for bypass Exam...

Page 2: ...number 1 ENTER CLEAR CMS phone number 1 key in 06 enter phone number 2 ENTER CLEAR CMS phone number 2 key in 08 enter 8888 8888 ENTER CLEAR account number Note to clear phone number replace digit wit...

Page 3: ...ch Connect a 500 ohm resistor in series with AUX of keypad black wire another wire connect to GRN of keypad green wire 500 ohm resistor 3 Partitioning key in 086 ON key 8 ENTER CLEAR to enable partiti...

Page 4: ...setting in address 053 should be 004 and above to avoid false alarm caused by vibration sensors For Fire zone connections using 4 wire smoke detector Once zone 3 is enable as FIRE zone in this zone d...

Page 5: ...r 3 seconds For Fire zone connections using 2 wire smoke detector Z1 Z2 Z3 Z4 Note Maximum up to 5 pcs 2 wire smoke detector 1 K 2 2 K 1 C 2 3 C 2 wire Smoke detector NO PGM AUX AUX 1 K 2 2 K 1 K 2 2...

Page 6: ...in the programming mode ENTER key is flashing Press ENTER 2828 8 CLEAR to activate walk test mode Press ENTER 2828 8 CLEAR to de activate walk test mode To reset panel back to factory default 1 Remove...

Page 7: ...0 10 button for 3 seconds One touch STAY arming Press hold the key 11 STAY button for 3 seconds One touch INSTANT arming Press hold the key 11 STAY button for 3 seconds then again Press hold again th...

Page 8: ...me for zone Press hold any button from 1 to 6 for 3 seconds Button 1 for zone 1 button 2 for zone 2 To activate deactivate chime for keypad zone Press hold button 8 To activate deactivate Buzzer Mute...

Reviews: