7
User functions
Normal function:
Type
Action
Display on 636 keypad
Arming / Disarm
[Enter 4 digit user code]
ARM is ON
Stay arming
(Stay zone will be bypassed)
[STAY][4 digit user code]
ARM & STAY are ON
Force arming
(Zone opened will be
bypassed, it consider arm
when it closed back)
[FORCE][4 digit user code]
ARM is ON
Instant arming
(Delay zone becomes Instant)
[STAY][4 digit user code], during the exit
delay, hold [STAY] for 3 seconds
ARM & STAY are ON
Bypass
[BYP][4 digit user code][ON the button
corresponding to the zone], then [ENTER].
BYP is ON
To Reset smoke detector after
an alarm on zone 3
Press [CLEAR] and [ENTER] together
Default master code is [4747] or [474747]
Important note:
Stay zone features MUST enable in [Step 1], or else it will not function
One-Touch Arming:
One-touch REGULAR arming
Press & hold the [key 0/10] button for 3 seconds
One-touch STAY arming
Press & hold the [key 11/STAY] button for 3 seconds
One-touch INSTANT arming
Press & hold the [key 11/STAY] button for 3 seconds, then again Press
& hold again the [key 11/STAY] button for 3 seconds
Panic function:
Press [1] & [3] at the same time, for AUDIBLE POLICE PANIC alarm.
Press [4] & [6] at the same time, for AUDIBLE MEDICAL alarm.
Press [7] & [9] at the same time, for FIRE alarm.
Change Master / create new user code:
Press [ENTER] [Master code – 4747] [ 2 digit section, 00 for master, 01 for user 1, 02 for user 2…], then
[4 digits new code][ENTER][ENTER]
E.g.:
[ENTER][4747][00] [5678][ENTER][ENTER], where 00 is master user and 5678 is the new master code.
[ENTER][5678][02] [2222][ENTER][ENTER], where 02 is user 2 and 2222 is the new user code.
[ENTER][5678][48] [5354][ENTER][ENTER], where 48 is user 48 and 5354 is the Duress code.
To delete user number
:
Press [ENTER] [Master code – 4747] [ 2 digit section, 02 for user 2, 03 for user 3…] [press
2ND][ENTER][CLEAR]
E.g.:
[ENTER][4747][02][Press 2ND][ENTER][CLEAR], user 2 is deleted.