background image

1

ESPRIT 728 ULT

Quick

Programming

Gui

de

V2.10

To enter Programming Mode:
1.

Press [ENTER]

2.

Enter [2828

]

or [282828]

(Enter key flashing),

you are in the programming mode

3.

Enter 3 digits ADDRESS number

4.

Enter required DATA

(Either enter 2 digits, 3 digits or ON / OFF relevant key)

Press [ENTER] to confirm or [CLEAR] to ignore

A=10, B=11/STAY, C=12/AWAY, D=BYP, E=MEM & F=TBL

Remember:

After keyed in a required DATA, always press ENTER and then CLEAR, in order to

let the

ENTER key flashing

before proceed with entering the next 3 digits ADDRESS number.

Step 1: To program zone type

Press [ENTER] [2828] or [282828], you are in the programming mode, ENTER key is flashing



ON relevant key [1 to 10] for ZONE features wanted

[key in 100][On key wants to be 24 HOUR zone]
[key in 104][ON key wants to be INSTANT zone]
[key in 108][ON key wants to be FOLLOW zone]

Note: Zones that are not selected in [100] to [108] automatically become delay zone.

[key in 096][ON key wants to be SILENT zone]
[key in 116][ON key wants to be STAY zone]
[key in 124][ON all zone to allow for bypass]

Example:
[key in 104], [ON key 2,3,4], meaning zone 2,3 & 4 are instant zone. Zone 1 is delay zone.
[key in 124], [ON 1,2,3, & 4], all zones are bypassable zone

Example:
[key in 116], [ON key 1, 3 & 4], meaning zone 1,3 & 4 are to be protected in stay arming, zone 2 is
bypassed.

Example:
[key in 100], [ON 3], meaning this zone 3 is a fire zone (24 hours zone)
Note: If zone 3 is enable as 24 hours zone, it is a FIRE zone

Example:
[key in 100][ON key 4], meaning zone 4 is 24 hours zone
[key in 096][ON key 4], meaning zone 4 is a silent zone (for panic button)



ON relevant key [1 to 10] for USER features wanted

[key in 062][ON key 1 to 10], to allows user 1 to 10 in stay arming
[key in 068][ON key 1 to 10], to allows user 1 to 10 in away/ force arming
[key in 074][ON key 1 to 10], to allows user 1 to 10 to bypass zones

Note: By default, master code (as user 00) allows to force and stay arming.

Summary of Contents for ESPRIT 728 ULT

Page 1: ...es that are not selected in 100 to 108 automatically become delay zone key in 096 ON key wants to be SILENT zone key in 116 ON key wants to be STAY zone key in 124 ON all zone to allow for bypass Exam...

Page 2: ...number 1 ENTER CLEAR CMS phone number 1 key in 06 enter phone number 2 ENTER CLEAR CMS phone number 2 key in 08 enter 8888 8888 ENTER CLEAR account number Note to clear phone number replace digit wit...

Page 3: ...ch Connect a 500 ohm resistor in series with AUX of keypad black wire another wire connect to GRN of keypad green wire 500 ohm resistor 3 Partitioning key in 086 ON key 8 ENTER CLEAR to enable partiti...

Page 4: ...setting in address 053 should be 004 and above to avoid false alarm caused by vibration sensors For Fire zone connections using 4 wire smoke detector Once zone 3 is enable as FIRE zone in this zone d...

Page 5: ...r 3 seconds For Fire zone connections using 2 wire smoke detector Z1 Z2 Z3 Z4 Note Maximum up to 5 pcs 2 wire smoke detector 1 K 2 2 K 1 C 2 3 C 2 wire Smoke detector NO PGM AUX AUX 1 K 2 2 K 1 K 2 2...

Page 6: ...in the programming mode ENTER key is flashing Press ENTER 2828 8 CLEAR to activate walk test mode Press ENTER 2828 8 CLEAR to de activate walk test mode To reset panel back to factory default 1 Remove...

Page 7: ...0 10 button for 3 seconds One touch STAY arming Press hold the key 11 STAY button for 3 seconds One touch INSTANT arming Press hold the key 11 STAY button for 3 seconds then again Press hold again th...

Page 8: ...me for zone Press hold any button from 1 to 6 for 3 seconds Button 1 for zone 1 button 2 for zone 2 To activate deactivate chime for keypad zone Press hold button 8 To activate deactivate Buzzer Mute...

Reviews: