background image

1

1.

Introduction

2

2.

Controls and Indicators

6

3.

Installation

9

4.

Operation

14

5.

Configurable Parameters & Settings

19

6.

Obtaining Service

20

7.

Troubleshooting

21

8.

Replacing the Battery

22

9.

Specifications

25

10.

Limited Product Warranty

27

A1.

Declaration of Conformity

28

Table Of Contents

Summary of Contents for Minuteman Encompass EC1000RT2U

Page 1: ...ser s Manual Encompass RT On Line UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000519 R...

Page 2: ...6 3 Installation 9 4 Operation 14 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equi...

Page 4: ...AC wall outlet 3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where...

Page 5: ...od 8 The LCD displays the status of the UPS 9 Pressing the Enter button saves the changes made to the UPS settings 10 Pressing the Page Up button goes to the previous page or will change the UPS setti...

Page 6: ...utility power 6 The option slot is for option cords 7 The Battery Backup output receptacles The output receptacles are electrically wired into two segments to support the Load Shedding Function Labele...

Page 7: ...ation is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERVICE PERSONNELONLY Please read all of the WARNINGS and CAUTIONS before attempting to con nect the batteries WARNI...

Page 8: ...r hours every ninety days CHECKING THE SITE WIRING FAULT After plugging the UPS into the AC wall outlet check the Site Wiring Fault icon on the front panel of the UPS If the Site Wiring Fault icon is...

Page 9: ...ge condition occurs the UPS will transfer to the battery mode the inverter will turn on powering the connected equipment the On Battery indicator will illuminate and the audible alarm will sound once...

Page 10: ...re Once the Economy mode has been Enabled the LCD will display ECO and the Bypass Yellow LED will be illuminate Turn on the connected equipment one at a time OPTION SLOT The option slot on the rear pa...

Page 11: ...When the UPS detects a hardware and or internal fault the Fault icon will illuminate and the audible alarm will beep continuously The fault condition in some instances may be reset by turning the UPS...

Page 12: ...the UPS press the On but ton If UPS works normally the software has control of the UPS Charge the batteries for 8 hours and retest If the runtime is still less than expected the batteries may need to...

Page 13: ...to the skin and eyes and may be toxic QUALIFIED SERVICE PERSONNEL ONLY CAUTION Do not dispose of batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the...

Page 14: ...aximum Power Capacity 0 ms Typical 90 Full Load Resettable Circuit Breaker 50 or 60 Hz 6Hz autosensing 0 160VAC 55V load dependent 150VAC Nominal 2 Transfer Time Efficiency Line Mode Input Protection...

Page 15: ...t parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty parts Para Systems products that are depot repair...

Page 16: ...C1000RT2U Y EC1500RT2U Y EC2000RT2U Y EC3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date July 10 2017 Robert Calhoun Nam...

Reviews: