Para systems Minuteman Encompass EC1000RT2U User Manual Download Page 15

27

26

BATTERY SYSTEM

Typical Recharge Time

Typical Battery Life

Battery Module

3-5 years, depending on discharge cycles and ambient temp

BM0069

8-hours to 90% after full load discharge

Battery Type

Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid

Runtime: Full Load (minutes)

Runtime: Half Load (minutes)

10

10

3

2

SURGE PROTECTION AND FILTERING

Audible Noise at 1 m (3 ft.)

10/100/1000 Base-T surge protec-
tion let-through (as a percentage
of an a/-2 kV 1.2/50 us,
500 a 8/20 uS test)

Telephone line surge protection
let-through (as a percentage of an
a/-2 kV 1.2/50 us, 500a 8/
20 uS test)

Noise Filter

Surge voltage let-through (as a
percentage of an a/-2
kV)

Surge Response Time

Surge Current Capability

Surge Energy Rating

254 Joules

0 ns (instantaneous) normal mode; <5 ns common mode

<5%

normal and common mode EMI/RFI suppression

<55 dBA

<1%

<5%

6500 Amps total

ENVIRONMENTAL

Operating Temperature (max)

Operating/Storage Humidity

Operating Elevation

0 to 40

°

C (+32 to +104

°

F)

10% to 90% Non-Condensing

0 to 3,000m (0 to +10,000 ft)

PHYSICAL

Weight - Net

Size - Net   L X W X H
(rackmount brackets installed)

Size - Shipping
L X W X H

Weight - Shipping

16.0 x 18.9 x 3.5"
407x479x88mm

22.4 x 21.4 x 9.0"
570x544x228mm

REGULATORY COMPLIANCE

Safety and Approvals

cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /
R: 2014), FCC Class  A, CE certified, Energy Star certified, RoHS2
(EU Directive 2011/65/EU)

Storage Elevation

0 to 15,000m (0 to +50,000 ft)

Storage Temperature

-10 to +50

°

C (+14 to +122

°

F)

BM0070

BM0071

10

3

15

5

23.7 x 18.9 x 3.5"
602x479x88mm

30.9 x 23.2 x 9.0"
785x590x228mm

59.5 lbs
27.0 Kgs

65.7 lbs
29.8 Kgs

44.1 lbs
20.0 Kgs

49.6 lbs
22.5 Kgs

24.3 lbs
11.0 Kgs

29.5 lbs
13.4 Kgs

44.1 lbs
20.0 Kgs

49.6 lbs
22.5 Kgs

19.2 x 18.9 x 3.5"
487 x 479 x 88mm

25.6 x 21.4 x 9.0"
650 x 544 x 228mm

Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and
operated within specified conditions, against faulty materials or workmanship for a pe-
riod of three years from the date of purchase.  For equipment sites within the United
States and Canada, this warranty covers depot repair or replacement of defective equip-
ment at the discretion of Para Systems.  Depot repair will be from the nearest authorized
service center.  The customer pays for shipping the product to Para Systems.  Para
Systems pays ground freight to ship the product back to the customer.  Replacement
parts and warranty labor will be borne by Para Systems.  For equipment located outside
of the United States and Canada, Para Systems only covers faulty parts.  Para Systems
products that are depot repaired or replaced pursuant to this warranty shall only be
warranted for the unexpired portion of the warranty applying to the original product.  This
warranty applies only to the original purchaser who must have properly registered the
product within 10 days of purchase.

The warranty shall be void if (a) the equipment is damaged by the customer, is improp-
erly used, is subjected to an adverse operating environment, or is operated outside the
limits of its electrical specifications; (b) the equipment is repaired or modified by anyone
other than Para Systems or Para Systems approved personnel; or (c) has been used in
a manner contrary to the product’s User's Manual or other written instructions.

Any technical advice furnished before or after delivery in regard to use or application of
Para Systems’ equipment is furnished without charge and on the basis that it represents
Para Systems’ best judgment under the circumstances, but it is used at the recipient’s
sole risk.

EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES, EX-
PRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE.  Some states do not permit limitation of implied
warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSI-
BILITY OF SUCH DAMAGE.  Specifically, Para Systems is not liable for any costs, such
as; labor for on-site installation, on-site maintenance or on-site service, lost profits or
revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, cost
of substitutes, claims by third parties, or otherwise.  The sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Para Systems’ products and
the only obligation of Para Systems hereunder, shall be depot repair or replacement of
defective equipment, components, or parts; or, at Para Systems’ option, refund of the
purchase price or substitution with an equivalent replacement product.  This warranty
gives you specific legal rights and you may also have other rights which vary from state
to state.

No employee, salesman, or agent of Para Systems is authorized to add to or vary the
terms of this warranty.

Chapter 10:  Limited Product Warranty

140 Joules

Summary of Contents for Minuteman Encompass EC1000RT2U

Page 1: ...ser s Manual Encompass RT On Line UPS Series Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000519 R...

Page 2: ...6 3 Installation 9 4 Operation 14 5 Configurable Parameters Settings 19 6 Obtaining Service 20 7 Troubleshooting 21 8 Replacing the Battery 22 9 Specifications 25 10 Limited Product Warranty 27 A1 De...

Page 3: ...Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected CAUTION To reduce the risk of electrical shock in conditions where the load equi...

Page 4: ...AC wall outlet 3 To de energize the UPS completely disconnect the battery Life Support Policy As a general policy we do not recommend the use of any of our products in life support applications where...

Page 5: ...od 8 The LCD displays the status of the UPS 9 Pressing the Enter button saves the changes made to the UPS settings 10 Pressing the Page Up button goes to the previous page or will change the UPS setti...

Page 6: ...utility power 6 The option slot is for option cords 7 The Battery Backup output receptacles The output receptacles are electrically wired into two segments to support the Load Shedding Function Labele...

Page 7: ...ation is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERVICE PERSONNELONLY Please read all of the WARNINGS and CAUTIONS before attempting to con nect the batteries WARNI...

Page 8: ...r hours every ninety days CHECKING THE SITE WIRING FAULT After plugging the UPS into the AC wall outlet check the Site Wiring Fault icon on the front panel of the UPS If the Site Wiring Fault icon is...

Page 9: ...ge condition occurs the UPS will transfer to the battery mode the inverter will turn on powering the connected equipment the On Battery indicator will illuminate and the audible alarm will sound once...

Page 10: ...re Once the Economy mode has been Enabled the LCD will display ECO and the Bypass Yellow LED will be illuminate Turn on the connected equipment one at a time OPTION SLOT The option slot on the rear pa...

Page 11: ...When the UPS detects a hardware and or internal fault the Fault icon will illuminate and the audible alarm will beep continuously The fault condition in some instances may be reset by turning the UPS...

Page 12: ...the UPS press the On but ton If UPS works normally the software has control of the UPS Charge the batteries for 8 hours and retest If the runtime is still less than expected the batteries may need to...

Page 13: ...to the skin and eyes and may be toxic QUALIFIED SERVICE PERSONNEL ONLY CAUTION Do not dispose of batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the...

Page 14: ...aximum Power Capacity 0 ms Typical 90 Full Load Resettable Circuit Breaker 50 or 60 Hz 6Hz autosensing 0 160VAC 55V load dependent 150VAC Nominal 2 Transfer Time Efficiency Line Mode Input Protection...

Page 15: ...t parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty parts Para Systems products that are depot repair...

Page 16: ...C1000RT2U Y EC1500RT2U Y EC2000RT2U Y EC3000RT2U Y I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date July 10 2017 Robert Calhoun Nam...

Reviews: