4.  CONTROLS AND INDICATORS 
 
4.1  Handgrip  controls ( Figure 2 ): 

 
TALK/RING/MONITOR  Switch

. This three-position slide switch is located under 

the handgrip just above microphone. The switch is labeled as MONITOR for high 
impedance monitoring, RING for ringer , and TALK for off-hook 

 

In the MONITOR position, the Handset is a high impedance coupling to the 
telephone line. This allows for telephone line monitoring without current drawing 
from the lines so not making any interrupt to conversation on telephone lines.  

 

In the RING position is on-hook with electronic ringer for in-coming  call alert. On 
this position If unit  touch to AC lines ringer will alarm with continuously ringing 
sound which user should disconnect handset from the lines immediately and 
carefully 

 

In the TALK position, the Handset is off-hook and may be used for dialing and 
talking. In this mode, the Handset performs as an ordinary telephone. 

 

All positions will not disrupt to data service on xDSL and High speed network 
 

PULSE/TONE Switch

. This two-position slide switch, labelled PULSE/TONE, is 

located under the handgrip just below the receiver. The switch selects the 
signalling output : TONE for DTMF or PULSE for dial pulse. 
 

4.2  Keypad Controls and indicator (Figure 3) :  

 
Keys     

The 12 standard keys will send either DTMF Tones or Pulses, depending  

on the PULSE/TONE switch setting.  And also 3 functional keys  

 
Last Number Redial Button. “R” 

   serves as a last number dialled key  

(Figure 2). The number may be redialled in either pulse or tone mode, as selected 
by the PULSE/TONE switch  

 
Polarity LED

  This red LED is Located just below the keypad. The LED indicates 

line polarity. The LED will not light if the red test lead is connected to the Ring 
(negative) side of the line and the black test lead is connected to the Tip( positive) 
side of the line. The red LED with light if the test leads are reversed : that is, with 
the red test lead connected to the Tip (positive) side and with the black test lead 
connected to the Ring (negative) side.  

 
5. OPERATION 

 

5.1.  Monitoring. by move the TALK/RING/MONITOR switch to the MONITOR 

position then connect the test lead clips to the line under test for audio monitoring 
in high impedance. This will not disrupt voice and data service to the line. 

   
       “Optional monitoring in medium impedance be done by moving switch to RING 

position for a higher sound level receiving”. 

 
 
 
 
 

Summary of Contents for LTS-48

Page 1: ...USER MANUAL TELEPHONE TEST SET DATA SAFE ...

Page 2: ...nd temporary communications 2 DESCRIPTION Physical Characteristics Figure 1 The case A is designed to give rugged service and withstand the rough handling normally associated with craft tools The keypad B has 15 buttons conductive rubber that is recessed into the receiver end of the housing The recessed bezel provides physical protection to the keypad and prevents accidental button operation The s...

Page 3: ...t 194 mv 12dBm Distortion to Tone level 20dB Frequency error 1 Level per Tone Pair 8 dBm min High versus Low Tone difference 4dB max Level variation 5 dB Physical Case Rugged and Withstand Nylon 6 6 Keypad 15 conductive rubber buttons Belt loop connect Spring loaded belt clip Test leads Tinsel wire PVC insulated with Nylon braided Jacket 1 5 meter long terminated by Bed of nail and Spike alligator...

Page 4: ...er the handgrip just below the receiver The switch selects the signalling output TONE for DTMF or PULSE for dial pulse 4 2 Keypad Controls and indicator Figure 3 Keys The 12 standard keys will send either DTMF Tones or Pulses depending on the PULSE TONE switch setting And also 3 functional keys Last Number Redial Button R serves as a last number dialled key Figure 2 The number may be redialled in ...

Page 5: ...off hook if need to dial again Note Operating on xDSL and data lines will not disrupt service on network during and after dialing 5 3 Polarity Check Move the TALK RING MONITOR switch to MONITOR then connect the lead clips to the line under testing Move the same switch from MONITOR to TALK with instruction described in 5 2 above The red LED will not light if the red lead clip is connected to the ri...

Page 6: ... ON OFF Move the TALK RING MONITOR switch to RING position and connect test leads to the telephone line The piezo electric transducer electronic ringer will ring whenever it detects ringing voltage on the lines Answer the call by moving the TALK RING MONITOR switch to TALK 6 CONNECTION Handset comes with test leads which one end terminated by RJ11 for connecting to Handset Handset designed with RJ...

Reviews: