12) Assembly and disassembly
When carrying out assembly and disassembly, always dis-
connect the mains plug in advance!
Loosen the screws on
the tube (7 pcs) (Torx10
screwdriver) Locked tor-
que max. 80Ncm.
Pull the fl ow conditioner
forward.
Remove cent-
re bolts (3 pcs).
Make sure that the impeller sits in the centre of the ca-
sing by screwing the large bolts. The fi ns of the impel-
ler must not touch the ca-
sing. Try to keep an equal
distance between the tip
of the impeller and the
wall of the casing. Turn
the impeller by hand to
check the distance in all
points.
If you loosen the M5x20
bolts (4 pcs) below the
adjustable foot, the
motor separates from
the basket. You can
then withdraw the mo-
tor forwards out of the
basket.
Do not overtighten the bolts, in order to prevent the
tube from being deformed. If necessary, you may have
to loosen an opposing bolt slightly so that you can
screw the other side in a little more!