Wave mode
The wave mode is used to generate waves in the
aquarium. After changing into the wave mode you can
change the parameters in the settings menu or the
quick change menu from the info screen. If the pump
is stopped (
STOP
button in the info or menu screen is
blinking) your settings will take eff ect when the pump
is restarted after you push the
STOP
button again.
Otherwise they will take eff ect immediately.
The Hydro Wizard
®
generates waves by changing
between two flow intensities. The flow intensities A
and B can be varied between 0% and 100%.
The Parameters „Time A“ and „Time B“ are used to
select the duration of each action.
Figure 11: information screen in wave mode
The parameter „Time A-B“ defi nes the duration of the in-
terval when the fl ow changes from „Flow A“ to „Flow B“.
The parameter „Phase delay“ is used when several
powerboxes and pumps are working in sync. It defi -
nes the delay in which the powerboxes wave is star-
ted later than the MASTER powerbox.
More information on connection several powerboxes can be found
under the chapter: „Connecting to the Panta Rhei CAN-Bus“.
To fi nd the ideal frequency in your aquarium select
FIND FREQUENCY
in the settings menu. Now select
the maximum fl ow strength. The wave frequency will
Flow B
Flow A
Time B-A
Time B
Time A
Time A-B
Phase
Current
flow
i
Summary of Contents for Hydro Wizard ECM 75
Page 1: ...Hydro Wizard ECM 75 Operating manual...
Page 3: ...Hydro Wizard ECM 75...
Page 4: ......
Page 17: ...Operating manual Hydro Wizard ECM 75 17...
Page 42: ...Operating manual Hydro Wizard ECM 75 42 16 Technical data a Pump characteristic curve...
Page 44: ...Operating manual Hydro Wizard ECM 75 44 c Dimensions all dimensions in mm Powerbox...
Page 45: ...Operating manual Hydro Wizard ECM 75 45 d Mount dimensions...