MON3-2A User Manual  P/N 821521 Rev-B.5

MSDI-1 SDI Option Field Upgrade

Section 3: Technical Information

We advise you to work with the unit on a clean, well lighted work bench.

Ensure the MON3-2A is disconnected from the power mains.

Remove top cover.  Retain screws for later reassembly.

Remove the blanking plugs from the BNC connector holes. (Rear panel sections 1B through 4B.)

Remove the flat ribbon cable from the rear I/O PC board. (Horizontal removal/insertion.)

Install the option kit-supplied flat ribbon connector into the connector previously vacated in Step 5.

Install the option kit-supplied power harness to the rear I/O PC board 4 pin header associated with the position
where this particular MSDI-1 option will be installed. (J22, J23, J24, or J25.) 

The RED wires are referenced

to the + symbol silk-screened on the circuit board.

Insert the flat ribbon into the rear (horizontal) flat ribbon connector on the MSDI-4 board.

Insert the flat ribbon cable to the front LCD into the inboard (vertical) flat ribbon connector on the MSDI-4 board.

Attach the MSDI-4 to the rear panel using the supplied nuts.

Attach the power harness to the 4 pin header on the MSDI-4. 

The RED wires go towards the marking “+12V.”

Double check all wiring and connections.

Connect an SDI signal to the SDI input and set the front panel Input (I/P) Selector Switch (Item 5 on page 10)
to the UP (B) position. Connect mains power to the unit and confirm operation.

Remove Mains power from the unit and repeat steps 4 through 13 for each monitor section receiving the option
installation. (We suggest each monitor section be individually installed and tested.)

Replace cover and return to service.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

15)

This section explains the procedures for field upgrading your unit for the MSDI-4 SDI option.

Summary of Contents for MON3-2A

Page 1: ...t Panel Features Rear Panel Features Section 3 Technical Information Tally Control Connector Wiring MSDI 1 SDI Option Field Upgrade MON3 2A 2U Triple LCD Video Monitor With Analog Inputs and Loop thro...

Page 2: ...ing walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only wi...

Page 3: ...NORAMAdtv ALL rights reserved 3 MON3 2A User Manual P N 821521 Rev B 5 Sect 1 General Features and Specifications General Features and Specifications Description Features Applications Specifications S...

Page 4: ...The LCD module circuitry automatically detects and indicates the presence of NTSC or PAL signals with front panel LED indicators Each LCD display has its own front panel trim pot controls for color t...

Page 5: ...ures and specifications subject to improvement without notice General Specifications Section 1 General Features and Specifications Operating Tempurature Indicators Connectors Standard Unit Dimensions...

Page 6: ...2001 PANORAMAdtv ALL rights reserved 6 MON3 2A User Manual P N 821521 Rev B 5...

Page 7: ...2001 PANORAMAdtv ALL rights reserved 7 MON3 2A User Manual P N 821521 Rev B 5 Operation Installation Front Panel Features Rear Panel Features Section 2...

Page 8: ...2001 PANORAMAdtv ALL rights reserved 8 MON3 2A User Manual P N 821521 Rev B 5 Section 2 Operation Installation Figure 2a MON3 2A Chassis Dimensions...

Page 9: ...l support rails Rear support is not required LCD Monitor Viewing Position To obtain the best operator s viewing angle mount the MON3 2A as nearly straight on to the operator s position as possible 0 d...

Page 10: ...ontrols TINT Tint adjust for desired image color hue NTSC only CHROMA Color Saturation adjust for desired amount of image color saturation BRIGHT Brightness adjust for desired screen brightness CONT C...

Page 11: ...2001 PANORAMAdtv ALL rights reserved 11 MON3 2A User Manual P N 821521 Rev B 5 Figure 2b MON3 2A Front Panel Features Section 2 Operation...

Page 12: ...ections to down stream equipment are supplied here If you supply down stream equipment from this connector ensure you set the TERM LIFT toggle switch Item D to the LIFT DOWN position If no other equip...

Page 13: ...APPROVED IS UL SEE SIDE FOR ADDI POWER SUPPLY 650 589 5676 FAX 650 589 1355 South San Francisco CA 94080 711 Grandview Drive PANORAMAdtv TERM LIFT 3A 2A IN CVBS 1A LOOP IN CVBS CVBS TERM LIFT LOOP CVB...

Page 14: ...option is required I CBAR On Toggle Switch MSDI 1 SDI Option This switch controls a color bar generator associated with each monitor To view the input signal place this switch in the DOWN position To...

Page 15: ...APPROVED IS UL SEE SIDE FOR ADDI POWER SUPPLY 650 589 5676 FAX 650 589 1355 South San Francisco CA 94080 711 Grandview Drive PANORAMAdtv TERM LIFT 3A 2A IN CVBS 1A LOOP IN CVBS CVBS TERM LIFT LOOP CVB...

Page 16: ...2001 PANORAMAdtv ALL rights reserved 16 MON3 2A User Manual P N 821521 Rev B 5 Section 2 Operation...

Page 17: ...2001 PANORAMAdtv ALL rights reserved 17 MON3 2A User Manual P N 821521 Rev B 5 Technical Information Section 3 Tally Control Connector Wiring MSDI 1 SDI Option Field Upgrade Instructions...

Page 18: ...the LEDs interface with TTL levels You can design illumination circuits as shown by using TTL buffers or by using transistors as switches TheTallyindicatorsarecapableofdisplayingthreecolors Illuminati...

Page 19: ...1 PANORAMAdtv ALL rights reserved 19 MON3 2A User Manual P N 821521 Rev B 5 Tally Control Connector Wiring Section 3 Technical Information Figure 3b MON3 2A Sample Tally Connections MON3 2A Tally Circ...

Page 20: ...4 or J25 The RED wires are referenced to the symbol silk screened on the circuit board Insert the flat ribbon into the rear horizontal flat ribbon connector on the MSDI 4 board Inserttheflatribboncabl...

Page 21: ...ghts reserved 27 MON3 2A User Manual P N 821521 Rev B 5 Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510 870 0810 Fax 510 870 0811 US Toll Free 1 888 596 4537 www panoramadtv c...

Page 22: ...Grandview Drive South San Francisco CA 94080 650 589 5676 Fax 650 589 1355 web www panoramadtv com e mail sales panoramadtv com Wohler Technologies Inc 31055 Huntwood Avenue Hayward CA 94544 Phone 510...

Reviews: