Following steps must be observed for adjustment of the lamp in this sequence:
1) With the aid of adjustment screws (1) and (2) the height of the lamp is moved in
relation to the optical axis.
2) With the projector switched on, examine the light distribution. Adjust screws (1)
and (2) accordingly.
3) Color shift: If the lamp is too far from the mirror, a blue color shift will appear; if too
close, a yellow shift will occur. Turn screw (3) until this effect disappears.
Adjustment screw (1) (2) (3)
Hexagonal key Nr. 4
Screw (4) is adjusted at the factory
DON´T TWIST!
5.2) Vertical Adjustment of the Projector
a) Rough Positioning:
For rough positioning, loosen the clamping lever on (1) both
sides and move the projector to the desired position. Re–tighten the lever.
b) Fine Adjustment:
For fine adjustment of the projektor turn the star grip (2) and
bring the projector into the exact position.
5.3) Yoke Assembly:„Standing“ or „Hanging“ Configuration
Separate the support yoke (8) (2 M 10 Nuts) and the telescope rails (7) on both sides
from the projector; Turn the support yoke around 180° such that it is mounted again
as a hanging yoke. Re-connect the telescoping
rails
.
5.4) Using the Tilt Angle Meter
For safe operation it is necessary to respect the tilt
range of the projector (see General Technical Data
on page 18).
Use the delivered Tilt Angle Meter by applying it on
the top edge of the projector (before operation). The
red locator indicates the actual tilt angle.
POSITION NUMBERS SEEPAGE 4