9910045 RevF
October
2020
PAGE
16
Lock Claw Insertion Gauge configuration and use
Place gauge against Lock Claw and underside
of module.
Select a Lock Claw which has been
confirmed to be installed correctly
through visual inspection.
The Tilt Arm and Lock Claw should
be aligned with the module frame
and the Lock Claw fully engaged
on the frame.
Mark line on gauge to finish setup.
Use gauge to confirm full Lock Claw
engagement-line must be visible.
9. Cam & Lock Claw Inspection
Inspect Cam side module connection
Module and Cam are near flush.
Module and Cam have a large
non-uniform gap.
Cam installation can be quickly visually
inspected (no gauge is available or
required) by comparing a known good
installation with all other installations.
Some gap between Module and Cam
is permissible. The graphics are
representative only; actual installation
geometry varies by module vendor
and part number.
If it is not clear the
module low side connection is good,
contact PanelClaw for assistance.
ALERT:
Verify correct installation by
lifting up on the module near the Cam
and making sure no movement occurs.