6. Install Module Low Side
PAGE
12
Cam Claw aligned
6.1
Cam Seat
Place module on Cam Seat and
align with Array Edge.
Ti
p: Ensure the module is vertical
and flush with Seat.
ALERT: Cam Claw mis-aligned.
R
Tip:
R dimension is found in
the Racking Construction Set.
Tip:
Installing modules
starting at the south array
edge provides more working
room and speeds installation.
ALERT:
Do not leave modules in
vertical position, go immediately to
next installation step (high side install).
Cam Claw
Place Cam Claw over module flange.
Apply a small downward force to
make sure it is properly seated.
6.2
ALERT:
Install Mechanical Attachments before installing modules.
See: 9910047 - Accessories Installation Manual
ALERT:
When forecasted wind gusts exceed 25% of
the wind speed listed in the site criteria table of the
Racking Construction Set, Deflectors must be installed
on all mounted modules to avoid possible system
damage.
Example of a typical good Cam Claw install,
after the module has been rotated down
and high-side has been installed