3.1  Mounting distance 
 

For easier maintenance, operation, and improved ventilation, be sure to install the PSR1 away from adjacent structures 
and  other  equipment.  See  the  following  drawings.  Be  sure  that  the  ambient  operation  temperature  and  the  ambient 
humidity are within their designated ranges.  

 

All dimensions are specified in mm

 

 

 

 
 
 

3.2  Inclined mounting 
 

When installing the PSR1 in a slanted panel, the panel face should not incline more than 30° 

 

 

 

 

 

 

 

 

 

 

 

 

            30° 

 

 
 

 

 

 

When installing the PSR1 in a slanted panel, and the panel face inclines more than 30°, the surrounding air temperature 
must not exceed 40°C. You may need to use forced air cooling (fan, A/C) to ensure the surrounding air temperature is 
40°C or below. 

 

Summary of Contents for PC PSR1-EP Series

Page 1: ...d to be accurate as of the date of publication however Panel S r l makes no warranty ex pressed or implied with regard to the products or documentation contained within this manual Panel S r l reserve...

Page 2: ...ons 9 2 6 Mechanical cut out 10 2 7 Chemicals and solvents resistance 11 Chapter 3 Installation and wiring 3 1 Mounting distance 13 3 2 Inclined mounting 13 3 3 Fasten PSR1 14 3 4 Connecting DC power...

Page 3: ...el it 3 3 Chapter 6 System setup 6 1 Installing operating system 25 6 2 Bios setup 25 6 3 Touchscreen driver and calibration 25 Chapter 7 Maintenance 7 1 Cleaning 26 7 2 Lithium battery 26 7 3 Spare p...

Page 4: ...ssemble or modify the Panel PC Doing so may cause a fire or an electric shock All tasks such as the installation commissioning and servicing of devices are only permitted to be carried out by qualifie...

Page 5: ...EN 55022 2010 Class B EMC EN 55024 2010 Class B LVD EN 60950 1 2006 A11 2009 A1 2010 A12 2011 LVD EN 62311 2008 LVD EN 62479 2010 RoHS EN 50581 2012 Energy Use Regulation EC no 617 2013 Energy Use Reg...

Page 6: ...rs or according to PANEL indisputable judgment to the replacement of the product itself The product under warranty must reach our headquarters equipped with the indication of the anomaly found and wit...

Page 7: ...Lake CPU Intel Core i3 7100T Intel Core i5 7500T Intel Core i7 7700T RAM 2x DDR4 SO DIMM 2133 MHz max 32 GB I O ports 2x Gigabit LAN 3x HDMI 2x RS232 2x RS232 422 485 4x USB 3 0 1x USB 2 0 1x Line Ou...

Page 8: ...Impact 3 0 mm DIA Steel Ball 9g Height 30 cm Static Load 500g within 10cm2 area for 30 sec Hardness 3H pencil pressure 1N 45 Speeling 800g cm by vertical 90 Reliability High temperature Humidity 70 C...

Page 9: ...5 0 single touch resistive PSR115 390 315 6 32 5 302 367 89 0 230 292 15 6 single touch resistive PSR116 430 275 6 52 5 302 407 94 0 230 252 17 0 single touch resistive PSR117 455 355 6 65 302 432 94...

Page 10: ...f retaining clips 12 1 single touch resistive PSR112 315 250 2 6 4 15 0 single touch resistive PSR115 370 295 2 6 4 15 6 single touch resistive PSR116 410 255 2 6 4 17 0 single touch resistive PSR117...

Page 11: ...ery acid Diacetone Alcohol Dioxan DS2 Decontamination fluid Fabric conditioner Acetonitrile Alkalicarbonate Ammonia 40 Bichromate Blown castor oil Ethylacetate Fluorochlorohydrocarbons Glycerine Glyco...

Page 12: ...lfuric Acid 5 0 2 Acetic Acid 10 0 10 Ethanol 50 0 10 Methanol 50 0 10 Gasoline 100 0 10 Kerosene 100 0 10 Acetone 100 0 1 Toluene 100 0 1 Solution of salt 3 0 10 Boil Water 100 0 0 25 Detergent Kao M...

Page 13: ...on temperature and the ambient humidity are within their designated ranges All dimensions are specified in mm 3 2 Inclined mounting When installing the PSR1 in a slanted panel the panel face should no...

Page 14: ...ix the Panel PC as shown 1 Insert each of the fasteners as shown 2 Be sure to pull the fastener back until it is flush with the rear of the attachment hole 3 Tightening the screws with too much force...

Page 15: ...correct rated input 24 VDC input voltage limits 18 36 VDC for PSR116 PSR117 PSR118 PSR119 PSR122 The DC power cable must be secured in the terminal block power connector as shown in the image Wires wi...

Page 16: ...to the central grounding point in the control cabinet using the shortest route possible A cable with a minimum cross section of 2 5 mm per connection should be used All data cables connected to the d...

Page 17: ...PC disconnect the power cable Isolate the system from all potential sources of electrical power Discharge any electrostatic charge on the ground connection 4 2 RAM installation RAM Memory slots Unscr...

Page 18: ...manent damage to the motherboard and the SO DIMM if you force the SO DIMM into the slot at incorrect orientation Step 2 Firmly insert the SO DIMM into the slot until the retaining clips at both ends f...

Page 19: ...lease make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you st...

Page 20: ...dware settings for the card before you start the installation 2 Remove the system unit cover if your motherboard is already installed in a chassis 3 Remove the bracket facing the slot that you intend...

Page 21: ...www panel it 21 21 Chapter 5 jumpers and connectors 5 1 Motherboard IMB 191 layout...

Page 22: ...ut Output Power Select JGPIO_PWR1 14 Digital Input Output Default Value Setting JGPIO_SET1 15 LVDS Panel Connector Only for IMB 190 IMB 191 eDP Connector on the Backside of PCB Only for IMB 190 E 16 P...

Page 23: ...bit LAN 1 B WI FI Antenna optional M HDMI 3 C 1x USB 2 0 N HDMI 2 D RS232 422 485 COM 1 O 2x USB 3 0 E RS232 422 485 COM 2 P 2x USB 3 0 F RS232 COM 3 Q Gigabit LAN 3 optional G RS232 COM 4 R Supply Co...

Page 24: ...f the motherboard CLEAR CMOS Jumper CLRCMOS1 allows you to clear the data in CMOS To clear and reset the system parameters to default setup please turn off the computer and unplug the power cord from...

Page 25: ...The removal or loss of the authenticity certificate implies the forfeiture of the operating system license contract Using the software without regular license is a legal offence This motherboard suppo...

Page 26: ...ned with water and detergent a screen cleaning agent or alcohol ethanol The cleaning agent should be applied to the cloth beforehand not sprayed directly on the device Aggressive solvents chemicals sc...

Reviews: