Installation for Industrial Plug
4
5
Properly seat plug into Plug Housing opening. Twist on the Flex
Tail. The plug must be fully pushed back into the plug housing
before torquing the flextail, to ensure proper fit to the mating jack
bulkhead. To obtain IP67 intrusion protection, the Flex Tail must
be torqued to 20 in-lbs. Recommended tool to achieve 20 in-lbs
is a 3/4" flare nut 6 point crowfoot attachment.
Tethered Cap option for sealing Industrial
Plug when not in use with Industrial Jack.