External Signal Type Selection (DSW3-6, DSW3-7)
. Selects the type of output
signal.
Repeat Print via External Signal (DSW3-8)
. Allows an external device to control
the reprint of the label in the print buffer.
RS232 Transmit/Receive Setting (located on RS232C I/F Module)
The PTR3E comes standard with a parallel port only. Contact Product
Management if serial port is required.
Data Bit Selection (DSW1-1).
This switch sets the printer to receive either 7 or
8 bit data bits for each byte transmitted.
Parity Selection (DSW1-2, DSW1-3)
.
These switches select the type of parity used
for error detection.
Stop Bit Selection (DSW1-4)
. Selects the number of stop bits to end each byte
transmission.
24
Section 3. Configuration
DSW3-8
SETTING
OFF
Disabled
ON
Enabled
1 2 3 4 5 6 7 8
ON
OFF
DSW3
DSW3
DSW1-1 SETTING
OFF
8 data bits
ON
7 data bits
1
OFF
DSW1
2 3 4 5 6 7 8
ON
DSW1-2
DSW1-3 SETTING
OFF
OFF
No Parity
OFF
ON
Even
ON
OFF
Odd
ON
ON
Not Used
1 2 3 4 5 6 7 8
ON
OFF
DSW1
DSW1-4
SETTING
OFF
1 Stop Bit
ON
2 Stop Bits
1 2 3 4 5 6 7 8
ON
OFF
DSW1
DSW3-6
DSW3-7 SETTING
OFF
OFF
Type 4
OFF
ON
Type 3
ON
OFF
Type 2
ON
ON
Type 1