Safety Warnings 

 
The DPoE Power Patch Panel Power System is for use in restricted access locations only.  It is suitable 
for mounting on concrete or other non-combustible surfaces. 
  
Always observe standard safety precautions during installation, operation and maintenance of this 
product.  Read the installation instructions before performing any work.  Only a competent technician who 
is aware of the hazards involved should carry out adjustment, maintenance or repairs.  Do not work on 
the system or connect or disconnect cables during periods of lightning activity.  Ultimate disposal of this 
product should be handled according to all national laws and regulations. 
 

WARNING: HAZARDOUS 

VOLTAGE AND ENERGY LEVELS ARE PRESENT THAT 

CAN PRODUCE SERIOUS SHOCKS AND BURNS

.  Only authorized, 

qualified, and trained personnel should attempt to work on this equipment.  

 

CAUTION: 

The plug end of the cords used to connect to the Alternating Current (AC) 
source are considered to be the primary disconnect means, and 
reasonable access must be given to the plug and receptacle area.   
 
The receptacle must be fed with a breaker or fuse according to the 
instructions in this guide. 

 

CAUTION: 

ALL RECTIFIERS EMPLOY INTERNAL DOUBLE POLE/NEUTRAL 
FUSING 

 

FCC Compliance Statement 

This device complies with Part 15 of FCC Rules.  Operation is subject to the following two conditions: 
 
1.  This device may not cause harmful interference, and 
2.  This device must accept any interference received, including interference that may cause undesired 

operation. 

 

WARNING: 

Changes or modifications to this unit not expressly approved by the party 
responsible for the compliance could void the user's authority to operate 
this equipment. 

Warranty Information 

 
Unless otherwise specified, all products presented in this user's guide are warranted against defects in 
material and workmanship for a period of one year from the date of invoice by 

PANDUIT

® Corp. to the 

initial purchaser.  During the warranty period 

PANDUIT

 Corp. will, at its discretion, either repair or replace 

products that prove to be defective.  For warranty service or repair, the product claimed to be defective 
must be returned to a service facility designated by 

PANDUIT

 Corp. Buyer shall prepay all the shipping 

charges to 

PANDUIT

 Corp. and if, in the opinion of 

PANDUIT

 Corp., the product is defective, 

PANDUIT 

Corp. shall pay shipping charges to return the product to Buyer.  However, Buyer shall pay all shipping 
charges, duties and taxes for products returned to 

PANDUIT

 Corp. from another country.  

PANDUIT

 

Corp. warrants that its firmware designed by 

PANDUIT

 Corp. for use with an instrument will execute its 

functions when properly installed on that instrument.  

PANDUIT

 Corp. does not warrant that the operation 

of the instrument or the firmware will be uninterrupted or error-free. 

 

 

 

 

i

 

 

Summary of Contents for PN380

Page 1: ...DPoE Power System User s Guide Issue 1 0 Part Number PN380 February 2005 2005 PANDUIT Corp All Rights reserved www panduit com...

Page 2: ...lies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including i...

Page 3: ...implied PANDUIT Corp specifically disclaims the implied warranties of merchantability and fitness for a particular purpose The remedies provided herein are Buyer s sole and exclusive remedies PANDUIT...

Page 4: ...rt Circuit and Current Limit 12 Troubleshooting 12 NIC Information 12 NIC Card Settings 13 Figures Figure 1 Individual AC Feed Wiring Architecture 4 Figure 2 DC Wire Diagram 5 Figure 3 Connecting to a...

Page 5: ...on 3 Table 4 Recommended AC Circuit Breaker and Wire Sizes 4 Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs 7 Table 6 Recommended Torque Settings 7 Table 7 PANDUIT Corpora...

Page 6: ...pport all the Powered Devices PD connected to the panel In these cases or in cases of multiple DPoE Power Patch Panels a larger power system is often required One option is to use the PANDUIT DPoE Pow...

Page 7: ...ch chassis should be fed from a dedicated AC branch circuit of a TN or IT power system CAUTION The plug ends on the power cords used for the AC connections are considered to be the primary disconnect...

Page 8: ...s of 10 from PANDUIT part number DPoEPWRF10 Fuses are also available from Littelfuse and Bussman Their part numbers are as follows Littelfuse 481 series 10 Amp fuse part number 0481010 Bussman Fast Ac...

Page 9: ...5 14 DC Output Wiring Sizing There are two main considerations for sizing DC wire ampacity and voltage drop Ampacity refers to the safe current carrying level as specified by U S based organizations s...

Page 10: ...rews The bulk DC connection may be used as a battery input or as an unfused bulk output The connections require a terminal lug 1 4 single hole lug with a max tongue width of 0 63 or less Size wires ba...

Page 11: ...e included power harness has two wires for the A feed power only pins 1 2 The DPoE Power Patch Panel supports an optional redundant B feed power option but the terminals and wire leads are not attache...

Page 12: ...with a minimum number of commonly available tools 1 2 flat blade and Phillips head screwdrivers Torque wrench 7 16 socket drive Wire and cable strippers PANDUIT part number CT 100 Wire and cable crimp...

Page 13: ...ng boxes until the chassis wiring is complete Power Plant Mounting and Wiring WARNING Ensure all AC and DC power sources are off and disconnected Mechanical Mounting The DPoE Power System chassis is i...

Page 14: ...wer System User s Guide Issue 1 0 Part Number PN380 IEC320 AC cord Cord Bracket Securing Screw Figure 5 Cord Bracket Figure 6 Chassis Rear View AC Connections 4 40 Screws Figure 7 Securing Cord Bracke...

Page 15: ...C connection requires properly crimped terminal lugs 1 4 single hole lug with a max tongue width of 0 63 or less Terminal lugs such as PANDUIT part number LCA4 14 L for use with 3 or 4 AWG stranded wi...

Page 16: ...lease the latch handle Pull the latch handle until the rectifier clears the rear connector on the chassis then gently slide it out of the rear connector With the latch handle open on the replacement r...

Page 17: ...latched into their respective slots Make sure all power and signal connectors are properly mated Table 8 Troubleshooting Alarm Problem Possible Solution DC OK LED is extinguished This rectifier has s...

Page 18: ...Power System EMS Webpage via IPSetup exe on the CD provided with the chassis DPoEPWRCM only The NIC card will also work with Telnet or SNMP NIC Card Settings The NIC card comes equipped with the follo...

Page 19: ...ature sensing device to use for battery temperature compensation Internal sensor or external temperature probes The controller will autosense when an external probe is attached and automatically adjus...

Page 20: ...t Number PN380 15 Parameter Description Default Setting High temperature alarm release NIC Card only The temperature value at which the controller will release a HIGH TEMP alarm For systems using the...