INSTRUCTIONS CM315E

For Technical Support: www.panduit.com/resources/install_maintain.asp

P

AN

Z

ONE

 Wall Mount Cabinets can be installed in a hinged right or hinged left 

application. For your installation, determine which side of the cabinet will hinge. 
The cabinet is shown hinged left. Mounting surface must have 

sufficient 

strength to support the cabinet with payload

. The mounting surface must also 

be flat and extend beyond the overall cabinet footprint. 

Step 1:

Remove door and side panels for ease of handling. Ensure rear latches are 
closed. Install (4) 3/8” mounting hardware (not provided) as shown in Location 
Footprint. Hardware should protrude 3/8” from wall. Mount the cabinet to the 
wall by hooking the keyholes over the protruding 3/8” mounting hardware. 
Once the cabinet is in place, carefully swing cabinet from wall and tighten the 
hardware securely. Re-install door and side panels. Door swing direction can 
be changed by rotating the door 180°. 

Ensure the plastic spacer is placed at 

the bottom of the door hinge. 

1/2” or 3/4” Conduit Knockout

2” or 2 1/2” Conduit Knockout

Step 2:

To reverse rear hinge direction.

Open cabinet, and remove the latch from the rear lock. Remove the rear lock and the 
lock hole grommet on the opposite side. Close the cabinet and remove decorative covers 
on hinges. Remove the thread forming screws & lockwashers from the hinges (M5), and 
latches (M4), and re-install the components on the opposite sides of the cabinet. Open 
the cabinet and re-install the lock and grommet on the opposite sides. Re-assemble the 
lock latch, ensuring it locks in the downward rotation (see below).

M5 Thread forming 
screws & lock-
washers

Hinge

Lock Hole
Grommet

M4 Thread forming

screws

Latch

Lock

Lock in downward 

rotation

To open cabinet, 
push latch release 
button to dis-engage 
latch.

Front Door 
with Lock

Plastic 

Page 2 of 11

Summary of Contents for PANZONE PZWMC

Page 1: ...tprint with Cabinet Open 25 0 Cabinet Width PANZONE Wall Mount Cabinet Part Numbers PZWMC Location Footprint PZWMC12W Cabinet with Windowed Door Parts Included 1 Extra Door Spacer 8 Keys 1 Roll of Tak...

Page 2: ...om wall and tighten the hardware securely Re install door and side panels Door swing direction can be changed by rotating the door 180 Ensure the plastic spacer is placed at the bottom of the door hin...

Page 3: ...net Jumper Grounding Kit Only 2 Recommended for direct 1 1 switch patching only 3 Recommended for direct 1 1 switch patching only 4 Default Rail Location Recommended for traditional patching with smal...

Page 4: ...k loop to prevent cable damage Route cable to point 1 secure to tie down with a TAK TY Next route cable across the bottom of the enclosure to point 2 secure to tie down with a TAK TY Route to the desi...

Page 5: ...uipment Rail Kits PZCHSM2 PANZONE Horizontal Slack Manager PZWMC12W Shown Cabinet with Window Door PZBR3 5 PANZONE 3 5 Bend Radius Post Kit PZCFK PANZONE Fan Kit PZBR3 PANZONE 3 Bend Radius Post Kit P...

Page 6: ...rio 1 Switches not exceeding 120 watts of total heat output use fan kit as shown Scenario 2 POE Power over Ethernet or switches totaling over 120 watts of total heat use two PZCFK fan kits or one PZWM...

Page 7: ...on for optimal mounting location s Screw Mounting Locations Figure 3 Bend Radius Post Installation Bend radius posts can be installed at any rack location using 1 12 24 x 2 5 1 12 24 x 1 5 for PZBR3 s...

Page 8: ...et and save cams for later use Figure 2 Remove the Cylinder Nut from the Combination Lock and insert the Spacer Ring over the Lock Cylinder Figure 3 Install the Combination Lock onto the Cabinet and t...

Page 9: ...ous lock Flat Washer Lock Washer and Retain ing Screw Figure 7 Set the lock to the factory combination 0 0 0 Test lock rotation direction Adjust cam angle if necessary To Change Combination Set the l...

Page 10: ...f 24 Port Patch Panels PZCHSM2 PZCHSM2 2 RU of Active Equipment 2 RU of Active Equipment 2 RU of Active Equipment PZCHSM2 PZCHSM2 PZCHSM2 2 RU of 24 Port Patch Panels 2 RU of 24 Port Patch Panels 2 RU...

Page 11: ...mended Mounting Locations for Bend Radius Posts Never cross over center line of horizontal slack manager with cable slack Typical patch cord length is 4 feet minimum Route patch cords as shown to avoi...

Reviews: