WARNING
Read and understand the instructions and safety information in this manual
before operating this tool. Failure to observe this warning can result in bodily
injury.
Warning
: Risk of fire. Battery can explode or leak and cause injury if installed
backwards, disassembled, charged, crushed, or exposed to fire or high tem-
perature.
CAUTION
Caution - Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation expos-
ure. The laser is emitted from the LC connector located at the top of the tool.
See the next page illustration for connector location.
l
Never point the laser into the eyes of others.
l
Do Not stare directly at the laser beam.
l
Do Not set up tool to work at eye level or operate the tool on a reflect-
ive surface as the laser could be projected into your eyes or the eyes
of others.
Viewing the laser output with certain optical instruments (for example, eye
loupes, magnifiers, and microscopes) within a distance of 3.9” (99 mm) may
pose an eye hazard.
Remove the batteries when storing for an extended period of time to avoid
damage to the tool should the batteries deteriorate.
TECHNICAL INFORMATION
l
Recommended Use
: With available launch cords and cradles only
l
Laser Diode Type
: IEC 60825-1 Class 1 Laser product
l
Connectors
: LC, SC, ST, single mode and multimode, Panduit con-
nectors only
l
Power Supply
: 2 size AA (type L91) 1.5volt Lithium Iron Disulfide bat-
teries, Max Discharge: 2.5 amp continuous, included. Size AA alkaline
batteries can be used at a reduced rate battery life. Tool can also be
powered without batteries through the power/data (5 VDC, 1 amp
max) port on the side of the tool.
l
Rated Battery Life
: Approximately 8 hours (continuous use)
l
Firmware Update
s: Use power/data port on the side of the tool to
connect to PC, visit www.panduit.com for latest firmware
l
Environment
: FOR INDOOR USE ONLY, Max altitude 2000m, Pol-
lution degree 2
l
Operating Temperature
: +32° F to +104° F (0° C to +40° C), <93%
RH, non-condensing
l
Storage Temperature
: -40° F to +158°F (-40°C to +70°C)
l
Overall Dimensions
: 2.1" H x 2.8" W x 9.1" L (53mm x 71mm x
231mm)
l
Weight
: 9.0 oz (255 g) without batteries
Tool Storage
After all connector terminations are complete, detach the launch cord from the tool by disconnecting the LC connector at the top of the tool. Detach the ferrule
adapter from the cradle and put dust caps on both ends of the launch cord. Place tool, launch cord, and cradle in a protective case.
Tool Use
This tool is to be used for the termination of Panduit OptiCam connectors only. The tool emits a non-visible laser beam, which, when used in conjunction with
the launch cord and cradle, aids in proper connector termination.
Tool Care and Handling
l
Laser tools are precision instruments, which should be handled with care. See Safety Precautions.
l
Avoid shock, vibrations, and extreme heat.
l
Avoid dust and water that could obstruct laser.
l
Keep tool dry and clean.
l
Check batteries regularly to avoid deterioration.
l