![Panduit OptiCam 2 FS133 User Manual Download Page 26](http://html.mh-extra.com/html/panduit/opticam-2-fs133/opticam-2-fs133_user-manual_751661026.webp)
OptiCam 2 FS133 Termination Tool User Manual
-
26
-
SC Connector and Boot
1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the
flange. The insertion mark should be at end of backbone.
2. Align the external chamfers on the front of the inner housing assembly with the
internal chamfers at the front of the outer housing.
3. Push the inner housing assembly into the outer housing until it snaps into place.
Once in place the outer housing should be able to move freely back and forth over
the inner housing and boot.
4. The connector can be re-terminated if needed. Make sure that the dust cap is on the ferrule. Grip the outer housing and
push the connector tip down onto a hard surface. The inner housing will release from the outer housing. Remove outer
housing. Slide the boot off the backbone. Un-cam the connector and remove the fiber.
CAUTION
: DO NOT push down without a dust cap installed on the ferrule. Doing so could damage the
pre-polished fiber end face.
5. Clean the ferrule end face with a dry wipe. Place the dust cap over the ferrule end.
6.
(Optional)
Orient the connector as shown with the connector key facing upward in the same
direction as the ‘A’, ‘B’ and ‘KEY’ markings on the duplex clip. Insert the connector into one
side of the clip on a slight angle and rotate into place. The upper and lower legs of the clip slide
over the connector and “snap” when the connector is in place. The connector is fully seated
once the top and bottom connector flanges are inside of the rectangular slots in the clip.
Repeat this procedure for the other connector, completing the duplexing step.
Note
: When making cable assemblies, be sure to follow the correct ‘A->B’ polarity cross-over
between connectors.