Table 11: DPoE™ Element Manager Log Messages
DPoE
™ Element Manager Log Messages
The following types of messages are generated within the
DPoE
™ Power Patch Panel network and are
displayed in the
DPoE
™ Element Manager logs. While most of these messages are generated by a
DPoE
™ Power Patch Panel in the network, several of these messages originate within the
DPoE
™
Element Manager when, for example, it looses communication with one of the panels in the network.
Message Category
Priority
Level
Description
Undiscovered Device – Cold Start
Advisory
The main software process (i.e., the device
agent) in a previously unknown device is now
up and running.
Device Agent – Cold Start
Advisory
The main software process (i.e., the device
agent) in a previously known device is now up
and running. The process will likely reset itself.
New Device Discovered
Advisory
The Discover capability has found a new
device.
PD Connected
Minor
A new Powered Device has been detected at
the panel.
PD Disconnected
Minor
A Powered Device has been disconnected.
PD Fault
Major
A Powered Device is unable to communicate
an acknowledgement.
Device Power Above Threshold
Major
The power consumption at the device has
risen above the Power Warning Threshold.
Device Power Below Threshold
Major
The power consumption at the device has
fallen below the Power Warning Threshold.
Fuse Blown
Critical
The internal safety fuse has opened due to a
catastrophic failure of the unit.
Port Physical Location Changed
Advisory
Location information of one of the ports has
changed using the
DPoE™
Element Manager.
Device Self-Test Failed
Critical
The Device self-diagnostic test has failed.
Device Self-Test Passed
Advisory
The Device self-diagnostic test has passed.
Trap Recipient Changed
Advisory
One of the traps associated with a particular
device was changed using the
DPoE™
Element Manager.
PD Detection Failure
Major
Device detected failure with one of the
Powered Devices.
Device Agent Lost Communication
Critical
DPoE™
Element Manager cannot
communicate with the specified device.
IP Address Changed
Advisory
The IP address at one of the devices has
changed using the
DPoE™
Element Manager.
Low Device Voltage
Major
Measured device voltage is below the
minimum allowable for PoE.
High Device Voltage
Major
Measured device voltage is above the
minimum allowable for PoE.
Location Information Changed
Advisory
The
DPoE™
device that was previously
discovered has not been relocated to another
location in the network.