AT-UHD-CLSO-601
5
Commands
APwrOffTime
Set the time interval, in seconds, before the command to power-off the display is sent, once an A/V signal is no
longer detected. Use the
sta
argument to display the current setting.
Example
APwrOffTime 120
Syntax
APwrOffTime X
Parameter
Description
Range
X
Time interval
5 ... 3600, sta
Feedback
APwrOffTime 120
Aspect
Sets the output aspect ratio. Use the
sta
argument to display the current setting.
Syntax
Aspect X
Parameter
Description
Range
X
Setting
full, overscan, underscan, letterbox, panscan, follow, sta
Example
Aspect 1 fill
Feedback
Aspect 1 fill
ASwOutTime
Sets the time interval, in seconds, before the unit automatically switches to another active input if no signal is
received from the current input. Use the
sta
argument to display the current setting.
Syntax
ASwOutTime X
Parameter
Description
Range
X
Time interval
3 ... 600, sta
Example
ASwOutTime 10
Feedback
ASwOutTime 10