background image

Atlona Manuals 

Switchers

AT-UHD-CLSO-601

Application Programming Interface

Multi-Format Switcher

w/Mirrored HDMI and HDBaseT Outputs

4K/UHD 6 Input

Summary of Contents for ATLONA AT-UHD-CLSO-601

Page 1: ...AtlonaManuals Switchers AT UHD CLSO 601 Application Programming Interface Multi Format Switcher w Mirrored HDMI and HDBaseT Outputs 4K UHD 6 Input...

Page 2: ...AT UHD CLSO 601 2 Version Release Date Notes 1 Aug 2022 Initial release Version Information...

Page 3: ...the display device DispCEC Activates CEC control DispIP Activates IP control DispRS Activates serial RS 232 control EQB Adjusts the bass EQ setting EQT Adjusts the treble EQ setting HDCPSet Sets the H...

Page 4: ...RHostName Displays the hostname of the AT UHD CLSO 601 RNR Configures video random noise reduction RS232para Sets the baud rate data bits stop bits and parity for the RS 232 port RS232zone Send a comm...

Page 5: ...the output aspect ratio Use the sta argument to display the current setting Syntax Aspect X Parameter Description Range X Setting full overscan underscan letterbox panscan follow sta Example Aspect 1...

Page 6: ...iption Range X Video Port HDMI1 HDMI2 HDMI3 HDMI4 VGA1 VGA2 PREVIOUS Parameter Description Range X Video Port 1 6 Y Audio Port 5 6 P Example ASwPrePort HDMI1 Example AUD In2 Ai6 Feedback ASwPrePort HD...

Page 7: ...on Feedback AutoDispOn on Commands AutoPwrMode Sets the auto power mode Specify the sta argument to display the current setting Example AutoPwrMode DISPAVON Syntax AutoPwrMode X Parameter Description...

Page 8: ...return the current value Syntax Blink X Syntax BNR X Parameter Description Range X Value on off sta Parameter Description Range X Setting off low medium high sta Example Blink on Example BNR medium F...

Page 9: ...ack CliIPAddr 192 168 1 61 CliMode Sets the login mode of the controlled device login requires login credentials non login no login credentials required Use the sta argument to display the current set...

Page 10: ...username Example CliUser BigBoss Syntax CliUser X Parameter Description Range X Username 20 characters max Feedback CliUser BigBoss CSpara Sets the baud rate data bits parity bit and stop bits for the...

Page 11: ...mmands for setting these timers on power on the display off power off the display Use the sta argument to display the current setting Syntax DispCEC X Example DispCEC on Feedback DispCEC on Parameter...

Page 12: ...play the current setting EQB Adjusts the bass equalizer to the specified level Levels can also be increased or decreased by increments of 1 When incrementally increasing or decreasing the current bass...

Page 13: ...mands HDCPSet Set the HDCP reporting mode of the specified HDMI port Some computers will send HDCP content if an HDCP compliant display is detected on reports to the source device that the display sin...

Page 14: ...e name of the command Input Selects the input source Syntax help X Syntax Input X Y Parameter Description Range X Command name optional Command Parameter Description Range X Interface HDMI VGA Y Index...

Page 15: ...specified input as either a 0 or 1 If a source is detected on the input then a 1 will be displayed Inputs with no source connected will display a 0 Example InputStatus1 Syntax InputStatusX Feedback I...

Page 16: ...and performs the same function as removing a user within the web GUI Refer to the User Manual for more information Example IPDelUser Minion2 Syntax IPDelUser X Parameter Description Range X User User...

Page 17: ...d off no login required Use the sta argument to display the current setting The default setting is on Example IPLogin off Syntax IPLogin X Parameter Description Range X Value on off sta Feedback IPLog...

Page 18: ...k 0 255 per byte Z Gateway router 0 255 per byte Feedback IPStatic 192 168 1 112 255 255 255 0 192 168 1 1 IPTimeout Specifies the time interval of inactivity before the TCP IP session is terminated W...

Page 19: ...t an option on the OSD use the Menu Sel command MIC Configures the microphone ducking settings atime attack time rtime release time sens trigger level reduce program decrease Syntax LVOL X Syntax Menu...

Page 20: ...set Syntax MReset Feedback Mreset This command does not require any parameters MVOL Adjusts the microphone to the specified level Microphone levels can also be increased or decreased by increments of...

Page 21: ...PollAddIn Adds source for analog polling Syntax OSD X Y Syntax OutAMute X Syntax PollAddInX Y Example OSD info on Example OutAMute on Example PollAddIn2 SV enables SV for VGA input 5 Feedback OSD info...

Page 22: ...port 1 VGA input 5 2 VGA input 6 Y Secondary port VGA COMP CV SV PrefTimg Sets the preferred timing of the input video signal Specify the sta argument to display the current setting Preferred Timing L...

Page 23: ...the unit will not start the auto power off timer This value specifies the time interval that must elapse after the display control on command is sent before the display power off command can be sent T...

Page 24: ...er state of the AT HDVS 210H U TX Syntax PWSTA Example PWSTA Feedback ON This command does not require any parameters RepCmdTime Sets the number of time a command will be sent Some devices may require...

Page 25: ...atus on off sta Parameter Description Range X Setting off low medium high sta RHostName Displays the hostname of the unit Execute the SHostName command to set the hostname RNR Configures video random...

Page 26: ...arameter Description Range V Zone 1 5 W Baud rate 2400 9600 19200 38400 56000 57600 115200 X Data bits 8 9 Y Parity bit 0 None 1 Odd 2 Even Z Stop bits 1 2 Commands RS232zone Sends commands to the con...

Page 27: ...SetCmd on CRLF Syntax SetCmd X Y Parameter Description Range X Action on off vol vol mute fbkoff fbkon fbkmute Y Command string String Feedback SetCmd on CRLF Commands SHostName Sets the hostname of...

Page 28: ...1 Feedback SnVOL 10 SnVOL SnVOL Parameter Description Range X Value 80 10 Parameter Description Range X Request sta dev System Displays the status of the AT UHD CLSO 601 Specify the sta argument for a...

Page 29: ...specified command to the display using IP Do not add a space between the command and the first argument Example TrigIP1 on Syntax TrigIPX Y Parameter Description Range X TCP 1 2 Y Command on off vol...

Page 30: ...e Unlock Syntax Unlock Feedback Unlock Unlock Unlocks the buttons on the front panel Also refer to the Lock command This command does not require any parameters Example VersionMCU Syntax VersionX Para...

Page 31: ...i 50 Hz 11 1920 x 1080p 50 Hz 12 1920 x 1080p 24 Hz 13 1920 x 1080p 25 Hz 14 1920 x 1080p 30 Hz 15 640 x 480 72 Hz 16 640 x 480 75 Hz 17 800 x 600 60 Hz 18 800 x 600 72 Hz 19 800 x 600 75 Hz 20 1024 x...

Page 32: ...pecify the parentheses as part of the command Refer to the examples below VOLMute Enables or disables volume muting Specify the sta argument to return the current setting Syntax VOL X Syntax VOLMute X...

Page 33: ...US International atlona com 408 962 0515 41 43 508 4321 40232 R1...