19
INSTALLATION INSTRUCTIONS
The installation must be performed by a qualified electrical contractor.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
•
The cut out sizes are:
Cut-size
Model
PI3200
560 x 490 mm
PI3300
560 x 490 mm
PI3500
750 x 490 mm
•
The plate is equipped with two fans located at the bottom. Please observe the distances
•
for the circulation of the ventilation air.
Ensure that there is a distance of 50 mm
•
between the hob and the wall or sides.
The
ventilation
distance
between
the
plate
base
and
the
upper
section
of
a
ventilated
oven or drawer,
must
be
at
least
20mm.
The
separation
distance
for
non-forced ventilation
ovens
must
be
greater
in
accordance
with
the
oven
manufacturer’s recommendations.
Stick the gasket (2) two
millimeters from the external
edge of the glass, after removing
the protection sheet (3).
CAUTION! Improper
installation and failure to
observe the ventilations
may lead to malfunction
or breakdown of the
device that is not
covered by the
manufacturer’s warranty.
Summary of Contents for PI3200