Panblast Notice to Purchasers and Users 

 
1.1.1

 

All products and equipment designed and 
manufactured by Panblast are intended for use 
by experienced users of abrasive blasting 
equipment and its associated operations and 
abrasive blasting media.  

 

1.1.2

 

It is the responsibility of the user to:  
-

 

Determine if the equipment and abrasive 
media is suitable for the users' intended 
use and application.  

-

 

Familiarize themselves with any 
appropriate laws, regulations and safe 
work practices which may apply within the 
users working environment. 

-

 

Provide appropriate operator training and 
a safe working environment including 
operator protective equipment (PPE) such 
as, but not limited to, safety footwear, 
protective eyewear and hearing protection. 

 

1.1.3

 

Panblast Standard Terms and Conditions of Sale 
apply. Contact your local Panblast office should 
you require any further information or 
assistance. 
 

1.2

 

! WARNING ! – READ THIS SECTION 

CAREFULLY BEFORE USING THIS 
EQUIPMENT/APPARATUS. 

 
1.2.1

 

Heavy metal paint, asbestos and other toxic 
material dusts will cause serious lung disease 
or death without the use of properly designed 
and approved air supplied respiratory 
equipment (SAR) by blast operators and all 
personnel within the work site area. 

 

1.2.2

 

The compressor must have adequate output 
and the plumbing between the compressor and 
the point of attaching the air supply hose must 
have sufficient capacity to supply the volume of 
air at the pressure required. 

 
1.3

 

Standard Safety Precautions 

 
1.3.1

 

Approved safety eyewear, hearing and footwear 
protection should be worn at all times by the 
operator and all personnel in the immediate 
area that may be exposed to any hazards 
generated by the abrasive blasting process.  

 

1.3.2

 

Suitably approved respiratory protection should 
also be worn when handling abrasive media, 
abrasive refuse dust and when carrying out any 
service/maintenance work where any dust may 
be present. 

 

1.3.3

 

Any work performed on electrical wiring or 
components  must  only  be  carried  out  by 
suitably qualified and registered electrical 
trades personnel.  

 

1.3.4

 

Under no circumstances should any safety 
interlocks / lockouts or features be altered or 
disabled in any way. 

 

1.3.5

 

All equipment must be isolated from the 
compressed air supply and electrical power 
prior to any service or maintenance work being 
carried out.  

 

1.3.6

 

All care must be taken by the operator when 
lifting  or  moving  equipment  or  components  in 
order to prevent injury. Blast pots must always 

be emptied of abrasive media before any 
attempt is made to move them. 

 

1.3.7

 

Any modification of the equipment or use of 
non-genuine PanBlast™ replacement parts will 
void warranty.   

 

1.3.8

 

Always check the Material Data Sheet (MSDS) on 
the abrasive being used to ensure that it is free 
of harmful substances, in particular, free silica, 
cyanide, arsenic or lead. 

 

1.3.9

 

Test the surface to be blasted for harmful 
substances, taking the appropriate measures to 
ensure the safety of the operator and all 
personnel. 

 

1.3.10

 

The operator should carry out a daily inspection 
before start up of all wearing and safety items 
to ensure they are in correct operating order. In 
particular check all hose couplings and nozzle 
holders, ensuring that all couplings have 
engaged correctly, the safety locking pins are 
fitted and in good order. Always install safety 
whip check cables at every connection. Ensure 
that the blast nozzle has been securely screwed 
into the nozzle holder and the nozzle holder 
has been secured to the blast hose correctly 
and all screws are engaged.  

 
2.0

 

INTRODUCTION 

 

2.1

 

Scope. 

These instructions cover the installation, 

operation and maintenance of the PanBlast™ 
AirScan Mobile CO Monitor. 

 

-

 

Read and follow all instructions before 
using this equipment. 

-

 

Failure to comply with all instructions can 
result in serious injury or death. 

-

 

In the event that the user or any assistants 
of the user of this equipment cannot read 
or cannot completely understand the 
warnings and information contained in 
these instructions, the employer of the 
user and his assistant must thoroughly 
educate and train them in the correct 
operations and safety procedures of this 
equipment.  

 

PRIMARY COMPONENTS 

 
The primary components of the PanBlast™ AirScan 
Mobile CO Monitor: 

1

 

AirScan Mobile CO Monitor with 220 VAC line 
cord. 

2

 

Operators Manual 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 1 

Summary of Contents for ZVP-PC-0080-00

Page 1: ...PRODUCT OPERATING MANUAL PANBLASTTM AIRSCAN MOBILE CO MONITOR Manual Number ZVP PC 0070 00...

Page 2: ...SECTION 1 GENERAL INFORMATION 2 INTRODUCTION 3 INSTALLATION 4 OPERATION 5 INITIAL SET UP 6 RESPONSE CHECK 7 OPERATING MODE 8 CALIBRATION 9 TROUBLESHOOTING GUIDE 10 PARTS LISTING...

Page 3: ...ectrical trades personnel 1 3 4 Under no circumstances should any safety interlocks lockouts or features be altered or disabled in any way 1 3 5 All equipment must be isolated from the compressed air...

Page 4: ...t off of fixed installations should be provided Sample line volume is critical keep line as short as possible 3mm 1 8 OD x 1 5mm 1 16 ID Polyurethane tubing is commonly used as the sample line althoug...

Page 5: ...put port provides the capability to introduce calibration gases to the instrument sensor when the calibration Run valve is in the calibration mode 8 Faceplate door screw 9 Internal sample flow regulat...

Page 6: ...assembly to the closed position and remove the test gas from the instrument test gas port 6 Move the RUN CAL switch to the RUN position 6 4 Check and confirm that the flow rate returns to the GREEN co...

Page 7: ...edle knob of the calibration valve assembly to open Monitor the flow bar graph display to ensure GREEN condition and allow the impurity free gas to flow for at least one minute Check the air quality i...

Page 8: ...board has two 2 12VDC output Molex connectors J3 and J5 shown in Figure 5 One is used to power the internal alarm horn the other is unused and can power an external low current alarm device Maximum cu...

Page 9: ...sor loosen the screw 8 Figure 3 and open the faceplate When the enclosure is open follow the directions listed below 1 Carefully remove the 2 screws from the sensor block and lift the block off the se...

Page 10: ...Contact manufacturer for service Alarm horn will not sound Faulty or unplugged horn Plug horn in Replace horn Bad air Air quality indicator is RED Check intake for contamination Out of calibration Re...

Page 11: ...t Parts Stock Code Description Qty BAC AF 0270 00 CO Test Gas 1 BAC AF 0271 00 Impurity Free Air Test Gas 1 BAC AF 0269 00 Calibration Valve Assembly 1 BAC AF 0341 00 AirScan Sensor 1 BAC AF 0342 00 F...

Reviews: