2.

 

Important Safety Items

 

 

Welding power source 

Observe the following instructions to 
prevent the hazard. 

(1)Never use the welding power source for other 
than welding purpose. (e.g. Never attempt to use 
the welding power source for pipe thawing.) 
(2)It is very important to comply with all instructions, 
safety warnings, cautions and notes mentioned. 
Failure to do so can result in serious injury or even 
death. 
(3)Work of driving source at the input side, selecting 
work site, handling, storage and piping of high 
pressure gas, storage of welded products and also 
disposal of waste should be performed according to 
the operating instructions and national, state and 
local codes and regulations. 
(4)Prevent any unauthorized personnel to enter in 
and around the welding work area. 
(5)Pacemaker wearers should consult their doctor 
before going near arc welding. Magnetic fields can 
affect pacemakers. 
(6)Only educated and/or skilled persons who well 
understand this welding power source should 
install, operate, maintain and repair the unit. 
(7)Only educated and/or skilled persons who well 
understand the operating instructions of the unit 
and are capable of safe handling should perform 
operation of the unit. 
Against electric shock 

 

Observe the following instructions 
to prevent the hazard. 

(1)Do not touch live parts. 
(2)Grounding of the case of the welding power and 
base metal or a jig electrically connected to the 
base metal must be performed by educated and/or 
skilled persons. 
(3)Before installation or maintenance work, turn off 
power at the power box, wait it for at least five 
minutes to discharge capacitors. Significant voltage 
may exist on capacitors after turning off power at 
the power box so it is imperative to check to make 
sure that no charged voltage present at capacitors 
before touching any parts.  
(4)Do not use undersized, worn, damaged or bare 
wired cables. 
(5)Connect cables firm and insulate connection 
parts. 
(6)Keep all cases, panels and covers securely in 
place. 
(7)Do not handle the welding power source with 
torn or wet gloves. 
(8)Wear safety harness in case of working above 
floor level. 
(9)Turn off all equipment when not in use. 
 

(10)Perform periodic checks without fail and repair 
or replace any damaged parts before using the 
power source. 
Ventilation and protective equipment 

 

Oxygen deficit, fume and gas 
generated during welding can be 
hazardous. 

(1)When conducting welding in the bottom of the 
tank, boiler or hold as well as legally-defined sites, 
use a local exhauster specified by the applicable 
laws and regulations (occupational safety and 
health regulation, rules on preventing suffocation or 
etc.) or wear protective breathing gear. 
(2)To prevent dust injury or poisoning by the fume 
generated during welding, use a local exhauster 
specified by the applicable law (occupational safety 
and health regulation, rules on preventing injury by 
inhaled dust or etc.), or wear protective breathing 
gear. 
(3)When conducting welding in a confined area, 
make sure to provide sufficient ventilation or wear 
protective breathing gear and have a trained 
supervisor observe the workers. 
(4)Do not conduct welding at a site where 
degreasing, cleaning or spraying is performed. 
Conducting welding near the area where any of 
these types of work is performed can generate toxic 
gases. 
(5)When welding a coated steel plate, provide 
sufficient ventilation or wear protective breathing 
gear. (Welding of coated steel plates generates 
toxic fume and gas.)  
Against fire, explosion or blowout 

 

Observe the following cautions to 
prevent fires explosion or blowout. 

(1)Remove any combustible materials at and near 
the work site to prevent them from being exposed to 
the spatter. If they cannot be relocated, cover them 
with a fireproofing cover.  
(2)Do not conduct welding near combustible gases. 
(3)Do not bring the hot base metal near 
combustible 
materials immediately after welding. 
(4)When welding a ceiling, floor or wall, remove all 
flammables including ones located in hidden 
places. 
(5)Properly connect cables and insulate connected 
parts. Improper cable connections or touching of 
cables to any electric current passage of the base 
metal, such as steel beam, can cause fire.  
(6)Connect the base metal cable at a section 
closest to the welding part. 
(7)Do not weld a sealed tank or a pipe that contains 
a gas. 
(8)Keep a fire extinguisher near the welding site for 
an emergency. 

Summary of Contents for YD-400AT

Page 1: ...r your purchase of Panasonic welding power source Before operating this product please read the instructions carefully and save this manual SPEC No YD 400AT3HJE Panasonic Welding Systems Tangshan Co Ltd TSM50855 Operating Instructions Model No YD 400AT ...

Page 2: ......

Page 3: ...nce Please bear in mind that this product may not be brought as is into the EU The same restriction also applies to any country which has signed the EEA accord Please be absolutely sure to consult with us before attempting to relocate or resell this product to or in any EU member state or any other country which has signed the EEA accord ...

Page 4: ...y Items 2 Summarize 5 Rating 5 Preliminary Arrangements for Operation 6 Function 8 Connections 9 Operation 9 Maintenance and Inspection 10 Caution 11 Check Points for Abnormal Operation 11 Circuit Diagram 12 Apart Layout Drawing 13 Parts List 14 ...

Page 5: ......

Page 6: ...t and periodical check of this product Any problem arising out of any force majeure including but not limited to act of god Any malfunction or defect of this product that is directly or indirectly the result of any malfunction or defect of one or more related parts or products that are not supplied by PWST Or any problem arising out of or directly or indirectly attributable to the combination of t...

Page 7: ...rking above floor level 9 Turn off all equipment when not in use 10 Perform periodic checks without fail and repair or replace any damaged parts before using the power source Ventilation and protective equipment Oxygen deficit fume and gas generated during welding can be hazardous 1 When conducting welding in the bottom of the tank boiler or hold as well as legally defined sites use a local exhaus...

Page 8: ...he wire feeder or hand finger s hair or part of your clothes may be caught by the parts resulting in injury 2 Keep all covers panels and cases closed when using the product 3 Maintenance work and repair should be perform only by educated and or skilled persons who thoroughly understand welding machines While performing maintenance work or repair work provide fence or the like around the welding ma...

Page 9: ...ntained according to the manufacture s recommendations c The welding cables should be kept as short as possible and should be positioned close together running at or close to the floor level d Confirm to connection of all metallic components in the welding installation and adjacent to it should be considered for safety e The work piece should be connected to earth for electric safety f Selective s...

Page 10: ... 1 Model Item YD 400AT3HGH YD 400AT3HJE Rated Input Voltage V 380 415 No of Phases 3 phase Facility kVA 30 or more Input protective device Fuse A 40 No fuse breaker Earth leakage breaker A 50 Input Cable mm 2 6 or more Output Cable mm 2 35 or more Cable mm 2 Equal to or greater than the input side welding power source Notice Please unpack and take off the plastic sheet before using Make sure that ...

Page 11: ... the following Electrode holder and base metal cable self prepared according to the table 5 2 4 Installation and place The following conditions should be met for proper operation of the machine Indoors free from moisture dust or dirt In a place not exposed to direct sunlight or rainfall In a place where ambient temperature is between 10 40 In a place 20cm or more apart from the wall In a place whe...

Page 12: ...mp will flicker quickly twice every second and there s no output Corresponding to this phase lost there s neither display nor output when the other tow phases are lost sepataeely or together 8 Control switch When using remote controller please switch it to REMOTE otherwise switch it to RANEL 9 Prevent electric shock switch Switch it to ON that will protect the operator against electric shock It s ...

Page 13: ...op board 1 Remove the bolts on the side boards and detach the side boards 2 Remove 2 bolts and 2 eyebolts on the top board and draw out the top by uplifting its foreside Daily Inspection Please deal with these troubles in time or contact your dealer for help at detecting some abnormity during the inspection 1 Is there any extraordinary vibration or noise or smell 2 Is there any hot evidence in the...

Page 14: ...The operation of the power switch in the frontal panel When the power is automatically switched OFF never re switch ON the power again Please contact your dealer for help If re switch ON the power without removing the trouble that may enlarge the trouble or damage the power source Turn off the power switch waiting for more 2 3 minutes after finishing welding so that the fan wound cool the power so...

Page 15: ... duty Warning lamp of voltage lights ever bright The input voltage is over high over 498V or over low less 332V adjust the input voltage to the normal Warning lamp of voltage lights flicker twice quickly every one second losing of certain phase Check out the cause of the losing of certain phase Weld machine has neither display nor output when the other tow phases are lost separately or together Ch...

Page 16: ...11 12 Circuit Diagram TSMPA205 ...

Page 17: ...12 13 Apart Layout Drawing 5 1 2 4 3 6 7 8 10 11 12 13 14 15 16 17 18 20 21 24 22 25 26 27 28 30 31 30 28 32 29 23 0 19 9 ...

Page 18: ...S1 Display A V switch SR W102A 30BB 1 13 S2 Control switch SR W102A 30BB 1 14 Terminal TSM15748 2 15 Terminal TSM15748 1 16 FU1 FU2 Fuse 660GH63ULTC 2 17 Cooling fan 6C 230B 2 18 T1 Control transformer TSMU1059 415V TSMU0270 380V 1 19 CO1 Plug socket MT25B6YPM 1 20 MTr Main transformer TSMT0032 415V TSMT0031 380V 1 21 D2 D3 Diode FRS300BA50F or MMF300YB050U 2 22 L1 Reactor TSMLU235 1 23 Out subass...

Page 19: ...applies to any country which has signed the EEA accord Please be absolutely sure to consult with us before attempting to relocate or resell this product to or in any EU member state or any other country which has signed the EEA accord The standard of the product This product is designed and manufactured according to GB T 15579 1 2013 IEC 60974 1 2017This product may not conform to the local laws a...

Page 20: ......

Reviews: